High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

Load Capacitor

HRC 1500kV/2nF Ultra-High Voltage Divider - 4000:1 Ratio with <10pC PD @1.5MV

World-class 1500kV/2000pF capacitive divider system (3×6000pF series) with 4000:1 ratio, <10pC partial discharge, and 1650kV withstand capability.


  • US$ 25,160.00
  • Lead time: 30 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

HRC 1500kV/2000pF Ultra-High Voltage Divider System

Configuration: Three-stage series connection (3×6000pF units)

System Specifications

ParameterSpecificationStandard
Total Rated Voltage1,500 kVrms @50HzIEC 60358-1 Class AAA
Withstand Voltage1,650 kV/1min (Δtanδ <0.02%)IEC 60060-1
Certified Ratio4000:1 (NIST-traceable)ISO/IEC 17025
Partial Discharge
  • <10pC @1500kV (100%)

  • <2pC @1050kV (70%)

IEC 60270 Class 0.5

Unit Configuration

Individual Capacitors

  • Quantity: 3 units in series

  • Unit Capacitance: 6,000 pF ±0.2%

  • Unit Voltage: 500 kVrms each

System Performance

  • Total Capacitance: 2,000 pF

  • Dielectric Loss: ≤0.2% @20±0.5°C

  • Phase Matching: ≤0.003° between units

Mechanical Design

  • Insulation System:

    • Ultra-clean epoxy-oilpaper composite

    • 12-layer capacitive grading per unit

    • 200mm nominal wall thickness

  • Corona Control:

    • Ø2500mm multi-stage corona rings

    • Surface gradient ≤5 kV/cm @1500kV

  • Mobility System:

    • Motorized rail transport platform

    • Active anti-vibration system

    • Laser-aligned leveling (±0.05° accuracy)

Installation Requirements

  1. Facility Specifications:

    • 25m minimum clearance to ground

    • Class 1000 cleanroom environment

    • ±0.1° system leveling

  2. Measurement Setup:

    • 150kV-rated hexa-shielded measurement cables

    • Quadruple-guard shield connection

  3. Energization Protocol:

    • 100kV steps (15min/step)

    • Real-time PD monitoring at each stage

    • Automatic emergency discharge

Calibration & Maintenance

ProcedureIntervalStandard
Full System CalibrationMonthlyIEC 61869-11
Unit Balance VerificationWeeklyIEEE Std 4-2013
Oil Condition AnalysisDaily (operational days)ASTM D877 Class 00

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message