>1600KV Range
HIVG 2600KV-390KJ Impulse Voltage Generator: High-Capacity Testing Solution
Advanced High-Voltage Testing System
The HIVG 2600KV-390KJ Impulse Voltage Generator delivers industry-leading performance for electrical insulation testing. With its 13-stage design and 390kJ energy capacity, this system generates precise lightning impulses, switching surges, and chopping waves up to 2600kV for comprehensive equipment validation.
Technical Specifications
Parameter | Specification |
---|---|
Rated Voltage | +2600kV |
Rated Energy | 390kJ |
Stages | 13 stages |
Stage Voltage | +200kV |
Charging Voltage | +100kV |
Generator Capacitance | 0.1153μF (26 x 100kV/3μF units) |
Generator Dimensions | Height: 9800mm, Weight: 14500kg |
Voltage Utilization | ≥90% (lightning, load <1000pF) ≥85% (lightning, load <3000pF) |
Precision Waveform Generation
1. Lightning Impulse Wave (IEC 60060-1)
Waveform: 1.2μs ±30% / 50μs ±20%
Peak Oscillation: <5% amplitude
Load Range: 0–3800pF
2. Switching Impulse Wave
Waveform: 250μs ±20% / 2500ms ±60%
3. Chopping Wave
Duration: 2–6μs
Dispersity: <100ns
Compliance with International Standards
IEC 60060-1/2 (2010): High-voltage test definitions & procedures
IEC 61083-1/2: Instrumentation for impulse measurements
ANSI/IEEE 4a, 376, 1122: Impulse strength measurement
ASTM D2484/D2518: Electrical insulation standards
GB311/GB16927: Chinese national testing requirements
Operational Performance
Synchronization: ±20% polarity sync at 20–100% rated voltage
Discharge Control: <2% uncontrolled discharge rate
Voltage Stability: Charging fluctuation <±1.0%
Sparking Range: 10–100% Un
Duty Cycle:
120s cycle at >66% rated voltage
60s cycle at <66% rated voltage
Industrial Applications
High-voltage transformer impulse testing
Power transmission equipment validation
Insulation coordination studies (IEC 60071)
Surge arrester performance verification
Research & development of HV components