Gas Insulated Test Transformer
HGTS 325KV/100KVA SF6 Gas Insulated Test Transformer
This precision-engineered test transformer combines 325KV capability in a compact 100KVA package, offering exceptional flexibility with dual-voltage operation and advanced safety features for both laboratory and field testing environments.
Core Specifications
Rated Capacity: 100kVA (compact design)
Dual Voltage Output: 162.5KV/0.31A (serial) or 325KV/0.31A (parallel)
LV Configuration: 2×0.6kV windings (83.3A each)
Impedance Voltage: <12% (low-loss design)
Partial Discharge: ≤5pC at rated voltage
Dual-Voltage Operation
Serial Connection Mode
Output: 162.5KV
Current: 0.31A
Ideal for precision measurements
Lower energy consumption
Parallel Connection Mode
Output: 325KV
Current: 0.31A
Maximum voltage capability
For insulation withstand tests
Performance Characteristics
Parameter | Specification |
---|---|
Waveform Deviation | <3% |
No-load Current | <10% |
Dielectric Loss | <0.5% |
Noise Level | ≤65dB |
Overload Capacity | 0.37A for 300s (120% rating) |
Overvoltage Withstand | 357.5KV for 60s |
Advanced Load Cycling Capability
Standard Test Cycles
800pF Load: 275KV, 15min on/15min off (8 cycles/day)
2000pF Load (High): 275KV, 2min on/15min off (8 cycles/day)
2000pF Load (Low): 145KV, 15min on/15min off (8 cycles/day)
Integrated Safety Systems
Current Monitoring
5/5 CT supervision on HV terminal
Real-time earth current monitoring
Operator protection system
Surge Protection
0.6kV surge arrestors on exciting winding
Designed for repeated discharge tests
Typical Applications
High-voltage component testing
Cable and insulator research
Transformer factory testing
University high-voltage labs
Field testing of power equipment
Operational Notes
Maintain proper cooling between cycles
Verify SF6 pressure before operation
Check CT monitoring system functionality