HGTS 300kV/150kVA SF6 Test Transformer - Precision High-Voltage Testing Solution

Laboratory-grade HGTS 300kV/150kVA SF6 test transformer featuring dual-voltage output (150kV/300kV), <3% waveform deviation, and 5/5 CT current monitoring for ultra-precise high-voltage measurements.


  • US$ 72,420.00
  • Lead time: 90 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

HGTS 300kV/150kVA SF6 Gas Insulated Test Transformer

Designed for precision high-voltage testing applications, the HGTS 300kV transformer delivers laboratory-grade accuracy with advanced safety monitoring through integrated 5/5 current transformer protection.

Technical Specifications

  • Rated Capacity: 150kVA

  • Dual Voltage Output: 150kV/0.5A (serial) or 300kV/0.5A (parallel)

  • LV Configuration: 2×0.6kV windings (125A each)

  • Waveform Deviation: <3%

  • Dielectric Loss: <0.5%

  • Noise Level: ≤65dB

Advanced Safety Features

Integrated Current Monitoring

  • 5/5 CT protection on HV terminal

  • Real-time current supervision

  • Operator safety guarantee system

Comprehensive Protection

  • 0.6kV surge arrestors on exciting winding

  • 120% current (0.6A) for 300 seconds protection

  • 110% voltage (330kV) for 60 seconds withstand

Precision Performance

ParameterSpecification
No-load Current<10%
Impedance Voltage<20%
Daily Operation20 minutes at full rating
InsulationSF6 gas, maintenance-free

Dual-Voltage Operation

Serial Connection

  • Output: 150kV

  • Current: 0.5A

  • Ideal for extended duration tests

Parallel Connection

  • Output: 300kV

  • Current: 0.5A

  • For maximum voltage requirements

Laboratory & Industrial Applications

  • High-voltage component research

  • Insulation material testing

  • Precision calibration standards

  • Educational laboratory experiments

  • Quality control in HV manufacturing

Why Choose This Testing Solution?

  1. Research-Grade Accuracy: <3% waveform deviation ensures reliable data

  2. Safety First: Integrated CT monitoring and surge protection

  3. Flexible Configuration: Dual-voltage outputs from single unit

  4. Maintenance-Free: SF6 insulation eliminates fluid maintenance

  5. Precision Engineering: Stationary casing ensures stable measurements

Note: The 20-minute daily operation limit ensures optimal transformer lifespan while meeting most laboratory testing requirements.