HGTS 270kV/405kVA SF6 Test Transformer - Dual-Voltage Heavy-Current HV Solution

High-capacity 405kVA gas insulated test transformer with dual-voltage output (135kV/270kV), 1.5A heavy current rating, and industry-leading ≤2pC partial discharge performance for critical HV testing applications.


  • US$1.00; Negotiated Price
  • Lead time: 120days

>>>WhatsApp Communication<<<

Product Details

Product Tags

HGTS 270kV/405kVA SF6 Gas Insulated Test Transformer

The industrial-grade HGTS 270kV/405kVA transformer redefines high-current testing capabilities with flexible dual-voltage operation and exceptional 405kVA capacity in a maintenance-free SF6 design.

Core Specifications

  • Rated Capacity: 405kVA (industry-leading for 270kV class)

  • Dual Voltage Output: 135kV/1.5A (serial) or 270kV/1.5A (parallel)

  • LV Configuration: 2×6kV windings (33.75A each)

  • Partial Discharge: ≤2pC at 270kV (≤1pC at 235kV)

  • Noise Level: ≤65dB(A)

Breakthrough Performance Features

Dual-Voltage Operation

ConnectionOutputCurrent
Serial135kV1.5A
Parallel270kV1.5A

Rugged Overload Protection

  • 120% current (1.8A) for 3 minutes - no thermal damage

  • 110% voltage (297kV) for 1 minute - insulation intact

  • Survives 3×270kV short-circuit breakdown tests

Precision Engineering

Unmatched Insulation Quality

  • PD levels <2pC at full rating (70% better than industry standard)

  • Dielectric loss <0.5% at 20°C

  • Winding insulation >1500MΩ (HV-LV-ground)

Industrial Durability

  • Continuous 30min operation at 100% rating

  • 20kV/1min LV winding withstand

  • 5kV/1min HV terminal withstand

Heavy-Current Applications

  • Cable Testing: Long-run HV cable commissioning

  • Switchgear Testing: GIS circuit breaker endurance tests

  • Transformer Factories: Production line quality validation

  • Research Facilities: High-current plasma experiments

  • Energy Sector: Substation equipment stress testing

Technical Superiority

  1. Current Capacity: 1.5A output enables testing of low-impedance loads

  2. Measurement Precision: <3% waveform deviation ensures lab-grade accuracy

  3. Safety: Integrated damping resistor protects during breakdown tests

  4. Reliability: Stationary casing withstands industrial environments

  5. Flexibility: Dual-voltage operation reduces equipment needs

Ideal For Demanding Test Scenarios:

  • High-current impulse testing

  • Extended duration withstand tests

  • Precision partial discharge measurement

  • Mission-critical equipment validation