High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

≤100kV Range

LQTT 50kVA/5kV High-Current Test Transformer | 10A Output | <0.5% Loss | Tank-Type Design

Tank-type 50kVA test transformer delivers 10A at 5kV with 120% overload capacity. <0.5% dielectric loss, ONAN cooling & built-in CT protection.


  • US$ 2,893.00
  • Lead time: 40days

>>>WhatsApp Communication<<<

Product Details

Product Tags


Technical Specifications

ParameterSpecification
Rated Capacity50 kVA
Output Voltage5 kV
Output Current10 A (High-Current Focus)
Input Voltage0–380 V
Rated Current131.6 A
Frequency50 Hz
Waveform Deviation≤3%
Dielectric Loss<0.5%
Overload Capability120% current (300s)
110% voltage (60s)
Insulation Strength3 kV/min (LV terminals to ground)
Protection SystemML-15/5 Current Transformer
CoolingONAN (Oil Natural Air Natural)
Thermal LimitsWinding: ≤65K
Oil: ≤55K
Dimensions (L×W×H)440 × 350 × 420 mm
Weight<65 kg

Key Advantages

✅ High-Current Performance
10A output at 5kV for testing current-intensive equipment like:

  • Low-impedance cables

  • High-wattage resistors

  • Busbar systems

✅ Built-In Safety Protection
Integrated ML-15/5 current transformer provides:

  • Real-time current monitoring

  • Automatic trip protection

  • Personnel safety compliance

✅ Ultra-Efficient Operation
<0.5% dielectric loss minimizes energy waste during extended tests

✅ Robust Tank Design

  • Superior EMI/RFI shielding

  • Enhanced mechanical protection

  • Optimal thermal management

✅ Extended Duty Cycle

plaintext

Operational Capability:
100% Voltage → 60 minutes
80% Load    → Continuous
120% Current → 300 sec
110% Voltage → 60 sec

Critical Applications

  • High-current withstand tests on cables and bus ducts

  • Switchgear and circuit breaker validation

  • Transformer and reactor commissioning

  • Ground grid and earthing system testing

  • High-wattage load bank simulation


Performance Highlights

1. Precision Waveform Quality

≤3% deviation ensures accurate testing per IEC 60060-1 standards

2. Thermal Resilience

Engineered cooling maintains safety margins:

  • Maximum winding rise: 65K

  • Maximum oil rise: 55K

Why This High-Current Solution?

"The LQTT 50kVA/5kV fills a critical niche in high-current dielectric testing where conventional transformers fail. Its tank design and 10A output make it ideal for:

  • Utility substation commissioning

  • Industrial equipment stress testing

  • Research labs developing high-power components
    Where conventional test sets lack sufficient current capacity."
    – Power Testing Applications Team


Order Information

Model: LQTT-50/5-TANK
Lead Time:40days;

Certification: IEC 60060-1 Compliant

Options:

  • 60Hz operation

  • Remote monitoring package

  • Custom voltage taps (e.g., 3kV/16.7A)

  • Mobile test platform with cable reels


>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message