≤100kV Range
Technical Specifications
Parameter | Specification |
---|---|
Output Voltage | 50 kV |
Rated Capacity | 7 kVA |
HV Current | 0.14 A |
Input Voltage | 0–380 V |
Frequency | 50 Hz |
Partial Discharge (PD) | <5 pC at 100% U<sub>H</sub> |
Waveform Deviation | ≤5% |
No-Load Current | ≤10% |
Impedance Voltage | ≤10% |
Overload Capability | 150% current (300s) 110% voltage (60s) |
Thermal Limits | Winding: ≤65K Oil: ≤55K |
Operational Duty | 60 min @ 100% voltage Continuous @ 80% load |
Insulation Strength | 3 kV/min (LV to ground) |
Cooling | ONAN (Oil Natural Air Natural) |
Key Advantages
✅ Ultra-High Voltage Precision
50kV output for testing critical high-voltage components with ≤5% waveform distortion
✅ Sensitive Partial Detection
<5pC PD measurement capability for early insulation fault detection (IEC 60270 compliant)
✅ Rugged Overload Performance
150% current surge tolerance (5 minutes)
110% voltage spikes (1 minute)
✅ Thermal Stability
Maintains safety margins during extended operation:
Winding temperature rise ≤65K
Oil surface temperature rise ≤55K
✅ Continuous Testing Capability
Operational Modes:
► Full Power: 60 minutes
► Sustained Testing: Unlimited at 80% load
► Emergency Overload: 150% for 5 min
Critical Applications
HV Cable Systems: 33-66kV class termination tests
Transformer Bushings: Dielectric withstand validation
Gas-Insulated Switchgear: PD measurement
Surge Arresters: Leakage current tests
Insulator Strings: Pollution flashover studies
Rotating Machines: Stator insulation integrity
Performance Highlights
1. Cylinder Design Advantages
Compact footprint for lab/field use
Optimized oil circulation for cooling
Reduced corona effects at high voltages
2. Precision Waveform Quality
<5% deviation ensures compliance with IEC 60060-1 standards
3. Safety & Reliability
3kV/min LV-ground insulation
ONAN cooling prevents hotspots
Automatic thermal protection
Why This 50kV Solution?
"The LQTT 50kV/7kVA bridges the gap between ultra-high voltage requirements and precision diagnostics. Its <5pC sensitivity and compact cylinder design make it ideal for:
Utility high-voltage labs
Cable manufacturer QC
Research institutions
Where 50kV+ testing demands uncompromised accuracy in constrained spaces."
– HV Engineering Team
Technical Comparison
Model | Voltage | PD Level | Key Advantage |
---|---|---|---|
LQTT-50/7 | 50kV | <5pC | Ultra-HV precision |
LQTT-30/15 | 30kV | <3pC | Enhanced PD sensitivity |
LQTT-20/20 | 20kV | <5pC | Portable field unit |
Order Information
Model: LQTT-50/7-CYL
Lead Time:40 days
Certification: IEC 60270 PD Testing Compliant
Options:
60Hz operation
Integrated PD monitoring system
HV divider with NIST-traceable calibration
Custom voltage taps (e.g., 40kV/0.175A)