High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

Monitoring

LQ610 DC HV Generator | 120kV Arrester & Cable Tester | GB 11032-89 Compliant

Portable DC high-voltage generator for MOA leakage tests, cable withstand testing, and insulation checks. Features 0.75U₁ capture, triple protection, and 120kV output.


>>>WhatsApp Communication<<<

Product Details

Product Tags

LQ610 DC High-Voltage Generator

*Arrester & Cable Testing | GB 11032-89 Compliant | Field-Ready Reliability*


Engineered for Critical DC Withstand Tests

The LQ610 is a next-generation DC HV generator designed for voltage withstand testing and leakage current measurement of metal-oxide arresters (MOA), power cables, and high-voltage equipment. Fully compliant with China's GB 11032-89 standard for no-gap ZnO arresters, it replaces legacy systems with advanced safety and portability.


Key Technical Innovations

FeatureTechnical AdvantageUser Impact
High Power Density50% smaller, 40% lighter vs. predecessorsOne-person transport & deployment
Triple ProtectionOver-voltage + Over-current + Zero-start cutoffPrevents operator/equipment hazards
0.75U₁ StorageAuto-captures leakage current at 75% max voltageMOA degradation analysis (GB 11032)
Programmable Timer1–60 min tests + audible alarmHands-free operation
Military-Grade ComponentsSilicon carbide HV rectifiers100,000+ test cycles reliability
Intuitive InterfaceDigital kV/mA display + rotary controlZero training time

Technical Specifications

ParameterSpecification
Output Voltage0–120 kV DC (5 kV steps)
Max Current5 mA (continuous)
Ripple Factor<1% (per IEC 60060-1)
Voltage Stability±0.5% (0–100% load)
0.75U₁ FunctionAuto-triggered storage & display
Timer Range1–60 minutes (1s resolution)
Safety StandardsGB 311.1, IEC 61010-1 CAT IV 120kV

Compliance & Applications

Standards Met

  • GB 11032-89: No-gap metal oxide arresters

  • DL/T 474.4-2018: DC withstand test procedures

  • IEC 60060-1: HV test techniques

Critical Tests Performed

EquipmentTest TypeLQ610 Function
ZnO ArrestersLeakage current @ 0.75U₁Auto measurement + storage
HV CablesDC withstand testRamped voltage + timer
TransformersInsulation resistanceConstant voltage leakage monitoring
SwitchgearPolarity verificationNegative/positive DC output

Workflow: Arrester Testing Example

  1. Connect

    • Clip HV lead to arrester top terminal

    • Ground base plate

  2. Program

    • Set Uₘₐₓ (e.g., 100kV for 110kV arrester)

    • Enable 0.75U₁ (75kV auto-capture)

  3. Ramp

    • Increase voltage to Uₘₐₓ at 1kV/s

  4. Hold

    • 10-minute timer starts (audible alert at end)

  5. Analyze

    • Record leakage current at 0.75U₁ (acceptance: <500μA)


Safety Systems

  • Zero-Start Interlock
    Prevents energization if control knob ≠ "0"

  • Emergency Cutoff
    <0.1ms shutdown on arc detection

  • Automatic Discharge
    Bleeds stored energy to <5V after test

  • Dual Grounding
    Redundant earth terminals (EN 50191)