High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

Monitoring

LQ608 Digital Partial Discharge Tester

Advanced PD tester for transformers, GIS, cables & arresters. Features AI diagnostics, 1pC sensitivity, 4-channel monitoring & full compliance.


>>>WhatsApp Communication<<<

Product Details

Product Tags



Advanced Detection for Critical Assets

This integrated PD testing system performs partial discharge measurement and monitoring across high-voltage equipment, enabling predictive maintenance and compliance with international standards.


Key Applications

EquipmentTest TypeDetected Defects
Power TransformersType tests & field monitoringWinding voids, insulation degradation
Instrument TransformersRoutine testingInternal delamination, moisture ingress
HV Circuit BreakersCommissioning checksContact erosion, SF6 decomposition
GIS (Gas-Insulated Switchgear)Continuous monitoringParticle contamination, spacer defects
Zinc Oxide Surge ArrestersDegradation analysisThermal runaway, valve plate deterioration
Power CablesLocation & severity assessmentWater trees, joint faults

Complete System Components

ComponentFunctionTechnical Specification
Main UnitSignal processing & analysis16-bit ADC, 100 MS/s sampling rate
PD SoftwareAI-driven defect classificationTF-Map® + PRPD pattern recognition
High-Frequency CTNon-invasive current sensing20kHz–30MHz bandwidth, >60dB dynamic range
Input UnitMulti-sensor interface4 isolated channels (UHF/TEV/Acoustic)
Calibration Pulse GeneratorReference signal injection5pC–50nC range, ±1% accuracy
Antenna AmplifierUHF signal enhancement300–1500MHz, 40dB gain
Input AdaptersEquipment-specific couplingBNC/TNC/N-type connectors

Technical Specifications

ParameterSpecification
Detection Range1 pC – 100 nC
Bandwidth20 kHz – 1.5 GHz
Sensitivity<1 pC (calibrated)
Measurement Channels4 simultaneous inputs
Display10.1" touchscreen with 3D PD mapping
ConnectivityWi-Fi 6, Ethernet, USB 3.2, Bluetooth 5.3
Safety RatingIEC 61010-1 CAT IV 600V

Diagnostic Capabilities

✅ Real-Time Monitoring

  • Live PD magnitude/phase display

  • Automated trend analysis
    ✅ Defect Localization

  • Time-domain reflectometry (TDR) for cables

  • UHF time-difference mapping for GIS
    ✅ Intelligent Reporting

  • IEC 60270-compliant reports

  • Severity grading (Normal/Caution/Critical)
    ✅ Noise Suppression

  • Adaptive digital filtering (30dB EMI rejection)

  • AI-based signal separation


Workflow: From Setup to Diagnosis

  1. Sensor Deployment

    • Attach HFCT/TEV/UHF sensors per equipment type

  2. Calibration

    • Inject pulse via calibration generator

  3. Measurement

    • Capture PD pulses across 4 channels

  4. Analysis

    • Software classifies defects using PRPD patterns

  5. Reporting

    • Generate PDF/Excel reports with actionable insights


Compliance & Standards

  • IEC 60270: PD measurement standards

  • IEEE C57.113: Transformer PD guidelines

  • CIGRE TB 814: GIS partial discharge monitoring

  • IEC 62478: High-voltage testing techniques