UHV Series Resonant Test System - AC Withstand Voltage Testing for Power Equipment

Professional UHV Series Resonant System for AC withstand voltage tests on cables, transformers & GIS. Features DSP technology, 3 working modes, and comprehensive protection functions.


  • US$1.00; Negotiated Price
  • Lead time: 90days

>>>WhatsApp Communication<<<

Product Details

Product Tags

UHV Series Resonant Test System for High-Voltage AC Withstand Testing

The UHV Series Resonant System is engineered for precision AC withstand voltage testing of critical power infrastructure including cross-linked cables, hydro generators, main transformers, and GIS equipment. Certified for municipal and county-level high-voltage test departments, this system sets the standard for electrical safety verification.

Product Parameters

The work environment

Environment temperature-100oC-50oC
Relative humidity≤90%RH
The altitude≤1000m

Main technical parameters and functions of the device

Rated Capacity324kVA
The input powerThree-phase 380V voltage, frequency: 50Hz
Rated Voltage54kV
Rated current6A
Working frequency30-300Hz
Device output waveformSine wave
Waveform distortion rateOutput voltage waveform distortion rate ≤1%
Working timeContinuous 60min is allowed under rated load; Overvoltage 1.1 times 1 min
Temperature riseTemperature rise ≤65K after continuous operation under rated load for 60min
The quality factorDevice Q≥30(f=45Hz)
Protection functionOver current, over voltage and flashover protection (see frequency conversion power supply for details)
Accuracy of measurementEffective value of the system is 1.5

Exciter transformer

Rated Capacity9kVA
The input voltage0-400V,Single phase
The output voltage3kV
structuredry type
WeightAbout 50kg

Variable frequency power supply

Rated output capacity18kW
Working power supply380±10%V (three-phase), power frequency
The output voltage0-400v, single phase
Rated input current45A
Rated output current45A
Voltage resolution0.01kV
Accuracy of voltage measurement1.5%
Frequency range30-300Hz
Frequency regulation resolution≤0.1Hz
Frequency stability0.1%
Running timeContinuous 60min at rated capacity
Noise level≤50dB

High voltage reactor

Rated Capacity54kVA
Rated Voltage27kV
Rated Voltage2A
inductance68 H/single section
The quality factorQ≥30(f=45Hz)
structuredry type
WeightAbout 75kg

Capacitor divider

Rated voltage60kV
High piezoelectric capacity2500pF
Dielectric losstgσ≤0.5%
Voltage division ratio1000:1
measurement accuracyValid value of 1.5
WeightAbout 10kg

Key Applications

  • Cross-linked cable commissioning tests

  • Transformer routine maintenance

  • Gas-insulated switchgear (GIS) diagnostics

  • Busbar insulation verification

  • Hydroelectric generator acceptance testing

System Configuration

Complete test solution includes:

  • Frequency conversion control power supply - Precision 0.1Hz stepping

  • Excitation transformer - Multiple tap configurations

  • High-voltage reactor - Modular design for flexible combinations

  • Capacitive voltage divider - ±1% measurement accuracy

  • Compensation capacitor (optional) - For extended range testing

Technical Advantages

Advanced Protection System

  • Multi-stage overvoltage protection (adjustable trip points)

  • Zero-start interlock safety circuit

  • Real-time system detuning detection

  • Sample flashover protection (≤1ms response)

Operational Features

  • Three test modes:

    1. Fully automatic - One-touch test sequencing

    2. Manual mode - Complete operator control

    3. Auto-tune with manual boost - Optimal balance

  • DSP-based platform with upgradeable firmware

  • 10.4" LCD with real-time sweep curve display

  • 500-test data storage with alphanumeric coding

Field Performance Benefits

  • 55% lighter than conventional test sets

  • Resonance point identification within 30 seconds

  • Customizable frequency sweep range (20-300Hz)

  • Industrial-grade IP52 enclosure for site durability

Compliance Standards

Meets or exceeds requirements of:

  • IEC 60270 Partial Discharge Measurement

  • GB/T 16927.1-2011 HV Test Techniques

  • DL/T 849.1-2019 Power Equipment Test Regulations

The UHV Series Resonant System represents the next generation of high-voltage test technology, combining advanced DSP control with practical field operation features for power utilities and electrical contractors.