<30kVA Range
30kVA Contact Voltage Regulator | 0-250V Precision Output | ONAN Cooled
⚡ 120A High-Current Output
🔄 Symmetrical Compensation Tech
🛡️ 2× Short-Circuit Withstand
High-Capacity Voltage Regulation for Industrial Applications
The LQDZ-30kVA contact voltage regulator delivers precision power control for demanding high-current systems. Featuring symmetrical compensation and reversed polarity circuitry, this single-phase regulator maintains ±0.5% voltage linearity during continuous 60-minute operation at full 120A load. Certified to IEC 60076 standards, it's ideal for transformer testing, industrial process control, and research facilities requiring stable 0-250V power.
Input: 220V AC ±10% | Output: 0-250V AC
Rated Capacity: 30kVA | Cooling: ONAN
Duty Cycle: 60 min @ 100% load | THD: ≤3%
Technical Specifications
Parameter | Specification | Standard |
---|---|---|
Rated Capacity | 30kVA | IEC 60076-11 |
Input Voltage | 220V AC ±10% | IEC 60038 |
Output Voltage | 0-250V AC | |
Output Current | 120A continuous | |
Waveform Distortion | ≤3% THD | IEEE 519 |
Full Load Duration | 60 minutes | IEC 60529 |
Frequency | 50Hz ±2% | IEC 60034-1 |
Regulation Type | Electrical Drive (Servo Motor) |
Technical Insight: Voltage Linearity
The reversed polarity circuit maintains precision through:
Linearity Error = |(Vactual - Videal)/Vmax| × 100% ≤ 0.5%
Where Videal = (Position/Max Position) × 250V
Advanced Control & Monitoring Systems
Precision Servo Drive
Brushless DC motor with 0.05° positioning accuracy
Programmable regulation profiles (0.1-20 V/s)
IP67-rated encoder feedback
Integrated Monitoring
Magnetic oil level/temperature indicator
Multi-position contact status display
Protection contacts for overtravel safety
Industrial Interlocks
Control table synchronization interface
Secondary switchgear integration
SIL-2 rated safety circuits
ONAN Cooling System Performance
Dual-Path Thermal Management
Oil Natural: Convection cooling through radiators
Air Natural: Optimized fin design for heat dissipation
Thermal Capacity: 70°C max winding temp @ full load
Coolant: IEC 60296 mineral oil (___ liters)
Performance Specifications
Characteristic | Value | Benefit |
---|---|---|
Regulation Speed | 0.1-20 V/s adjustable | Precise ramp control for sensitive loads |
Linearity Error | < ±0.5% FS | Consistent voltage across entire range |
Recovery Time | 120 min after full load | Faster return to service |
Position Accuracy | 0.05° (equivalent to 0.035V) | Micro-precision voltage control |
Certifications & Compliance
IEC 60076
IEC 61010-1
CAT IV 300V
IP54 Enclosure
RoHS 3
Download Technical Dossier
Thermal performance curves
Servo motor specifications
Installation foundation requirements
IEC compliance certificates
Interlock wiring schematics
⚠️ Critical Safety Notice
WARNING: This equipment operates at lethal voltages. Always:
• Use CAT IV PPE during operation
• Implement lockout/tagout procedures before servicing
• Verify dead-circuit conditions with certified detectors
• Maintain safe discharge distance during testing