High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

AC DC Divider

LQHVF/AC-DC 200KV Dual-Mode Voltage Divider - 50pF/800MΩ Compact HV Measurement

Compact LQHVF/AC-DC 200KV voltage divider with dual 50pF/800MΩ modes. Features ≤±1.5% accuracy, ONAN cooling, 2000:1 ratio, and lightweight <55kg design for field testing.


  • US$ 4,919.00
  • Lead time: 20days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHVF/AC-DC 200KV Dual-Mode Voltage Divider

Portable 50pF Capacitive & 800MΩ Resistive Measurement System with ONAN Cooling

     Ultra-Portable

Field-ready at just 55kg

🔄      Dual Mode

AC/DC 2000:1 ratio

❄️      ONAN Cooling

30 min continuous operation

📊      PV2-1 Compatible

100V output to voltmeters

Technical Specifications

ParameterValue
Rated Voltage200kV AC/DC
Frequency (AC Mode)50/60Hz
Capacitance (AC)50pF
Resistance (DC)800MΩ
Dividing Ratio2000:1 (AC & DC)
Output to PV2-1100V
Accuracy≤±1.5%
Dielectric Loss<0.5%
Max Test Voltage220kV
Operating Time30 min @100% load
Cooling SystemONAN (Oil Natural Air Natural)
Temperature Coefficient<0.0005
DimensionsØ150/Ø550 × 1600mm
Weight<55kg

Dual-Mode Measurement Capabilities

AC Measurement

  • 50pF Capacitive Coupling for AC circuits

  • 50/60Hz frequency compatibility

  • Dielectric loss <0.5%

  • Ideal for power frequency testing

DC Measurement

  • 800MΩ Resistive Load for DC systems

  • Ultra-stable <0.0005 temperature coefficient

  • No frequency dependence

  • Perfect for HVDC applications

Both modes maintain identical 2000:1 dividing ratio for measurement consistency

Compact Field-Ready Design

Portability Advantages

  • Lightweight 55kg construction

  • Compact Ø550mm footprint

  • Integrated carrying points

  • No external cooling required

Robust Construction

  • ONAN oil-immersed cooling

  • 220kV test-proven insulation

  • Corona-free terminals

  • Sealed environmental protection

PV2-1 Peak Voltmeter Integration

Pre-configured for seamless connection:

  • Standardized 100V output signal

  • Direct interface with PV2-1 instruments

  • Calibrated measurement path

  • No additional attenuation needed

⚠️ Note: Peak voltmeter not included - compatible with all PV2-1 series instruments

Applications

Mobile Test Labs

Lightweight design for on-site HV testing

Transformer Testing

AC/DC withstand voltage verification

HVDC Systems

800MΩ DC mode for converter stations

Research & Education

Compact solution for university labs

Safety & Compliance

  • Tested to 220kV (110% rated voltage)

  • IEC 60060-1 certified (High-voltage test techniques)

  • IEC 61010 compliant (Electrical safety)

  • ONAN cooling eliminates active failure points

⛑️ Field Safety: Maintain minimum 2m clearance during 200kV operation

Operational Guidelines

  1. Max continuous operation: 30 minutes at 200kV

  2. Cool-down period: Equal to operation time

  3. Annual dielectric oil analysis

  4. Biannual ratio calibration (NIST traceable)

  5. Storage at ≤60% humidity

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message