High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

AC DC Divider

LQHVF/AC-DC 250KV Dual-Purpose Voltage Divider - 100pF Capacitance & 600MΩ Resistance

Precision LQHVF/AC-DC 250KV voltage divider with 100pF/600MΩ dual-mode operation. Features ≤±1.5% accuracy, ONAN cooling, and 2000:1/2500:1 ratios for AC/DC testing.


>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHVF/AC-DC 250KV Dual-Purpose Voltage Divider

100pF Capacitive & 600MΩ Resistive Measurement System with ONAN Cooling

Key Advantages

  • AC/DC Dual Mode - 2000:1 AC & 2500:1 DC division ratios

  • ONAN Cooling Technology - Oil Natural Air Natural thermal management

  • Peak Voltmeter Integration - 100V output to PV2-1 instruments

  • Ultra-Stable Performance - Temperature coefficient <0.0005

  • 285KV Test Proven - Exceeds rated voltage by 14%

Technical Specifications

ParameterAC ModeDC Mode
Rated Voltage250kV
Frequency50/60HzN/A
Dividing Ratio2000:12500:1
Capacitance100pFN/A
ResistanceN/A600MΩ
Output Voltage100V (to PV2-1 peak voltmeter)
Accuracy≤±1.5%
Dielectric Loss<0.5%N/A
Max Test Voltage285kV
Operating Time30 min @100% load
CoolingONAN
DimensionsØ150/Ø600 × 1600mm
Weight<65kg

Dual-Mode Measurement System

AC Measurement Mode

  • 2000:1 voltage division ratio

  • 100pF capacitive coupling

  • 50/60Hz frequency compatibility

  • Dielectric loss <0.5%

DC Measurement Mode

  • 2500:1 voltage division ratio

  • 600MΩ resistive load

  • Ultra-low temperature drift (<0.0005)

  • No frequency dependence

Peak Voltmeter Integration

Directly interfaces with PV2-1 instruments:

  • Standard 100V output signal

  • Calibrated measurement path

  • No external attenuation needed

  • Note: Peak voltmeter not included

ONAN Cooling Advantage

Oil Natural Air Natural technology ensures:

  • Continuous 250kV operation for 30 minutes

  • Stable dielectric properties under load

  • No active components required

Applications

Factory Acceptance Testing

Verify HV equipment at 285kV test voltage

Research Laboratories

Precision AC/DC comparative measurements

Field Diagnostics

Portable 65kg design for on-site testing

Compliance & Safety

Meets international standards:

  • IEC 60060-1 (HV test techniques)

  • IEC 61010 (Electrical safety requirements)

  • IEEE 4 (Standard for HV testing)

Safety Margin: Withstands 285kV (14% above rated voltage)

Operational Guidelines

  1. Max continuous operation: 30 minutes at 250kV

  2. Cooling recovery period: Equal to operation time

  3. Annual dielectric oil analysis

  4. Biannual ratio verification

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message