100kv ~ 200kV Range
LQHVF 200kV/500pF: Ultra-Lightweight Dual-Function Capacitor
200kV Precision Measurement with Dual-Test Capability
The LQHVF 200kV/500pF capacitor revolutionizes high-voltage testing with its dual-measurement ports, exceptional thermal stability, and industry-leading lightweight design. Engineered for 60Hz power systems, this oil-immersed solution combines voltage division and coupling functions while weighing under 55kg—making it the lightest 200kV capacitor in its class.
"The only 200kV dual-function capacitor with integrated PD test port—delivering <10pC partial discharge at full voltage with exceptional <0.0005 temperature coefficient."
Dual-Function Design for Comprehensive Testing
Precision Voltage Measurement
1000:1 ratio with ≤±1.5% accuracy for reliable 200kV monitoring via dedicated voltmeter port
Integrated PD Testing
Dedicated partial discharge test port enables simultaneous diagnostics without reconfiguration
Technical Specifications
Parameter | Specification |
---|---|
Rated Voltage | 200kV |
Frequency | 60Hz |
Capacitance | 500pF |
Temperature Coefficient | <0.0005 (500 ppm/°C) |
Partial Discharge | <10pC at rated voltage |
Voltage Ratio | 1000:1 |
Accuracy | ≤ ±1.5% |
Dielectric Loss | <0.5% |
Continuous Operation | 60 minutes at 100% rated voltage |
Cooling | ONAN (Oil Natural Air Natural) |
Dimensions | 500mm diameter × 1600mm height |
Weight | <55kg |
Dual-Measurement Connector System
[Diagram Placeholder: Dual-port connection system]
Fig 1: HV measurement and PD test ports configuration
Connection Specifications
HV Measurement Port
Output: Scaled voltage (200:0.2kV)
Interface: BNC/SMA connector
Compatibility: Standard digital voltmeters
PD Test Port
Output: Raw PD signal
Interface: N-type connector
Compatibility: IEC 60270 compliant testers
Compact Cylindrical Design
Dimensions: Ø500mm × 1600mm (H)
Weight: <55kg
▶ 40% lighter than conventional 200kV capacitors ◀
Structural Advantages
Oil-Immersed ONAN Cooling: Mineral oil insulation with natural convection thermal management
Removable Components: Corona rings, LV arm, HV arm, and detachable base
Cylindrical Profile: Optimized for space-constrained substations and mobile labs
Aluminum Alloy Corona Rings: Prevents discharge and ensures stable performance
Performance Comparison
Feature | LQHVF 200kV/500pF | Standard 200kV Dividers |
---|---|---|
Weight | <55kg | 80-120kg |
Footprint | Ø0.5m | 0.8×0.8m+ |
Measurement Ports | Dual (HV + PD) | Single |
Temp Coefficient | <500 ppm/°C | 800-1500 ppm/°C |
Partial Discharge | <10pC | 15-30pC |
Key Advantages
Simultaneous Testing
Conduct voltage measurement and PD diagnostics concurrently via dedicated ports
Exceptional Thermal Stability
<500 ppm/°C temperature coefficient ensures accuracy across -25°C to +60°C range
Space-Optimized Design
Cylindrical profile (Ø500mm) fits confined spaces where rectangular units cannot
Easy Transport & Installation
55kg weight enables single-person deployment with standard lifting equipment
Industry Applications
Power Substations
Voltage monitoring and PD diagnostics in compact switchgear installations
High-Voltage Labs
Simultaneous measurement and discharge testing for transformer R&D
Field Testing
Mobile diagnostic units for transmission line maintenance
Renewable Integration
Wind/solar substation monitoring with space-efficient design
Compliance & Standards
IEC 60270: Partial discharge measurements
IEC 60358-1: Coupling capacitors & capacitor dividers
IEEE 4: High-voltage testing standards
ANSI C93.1: Power line carrier coupling
EN 62155: Hollow pressurized ceramic insulators
Operational Benefits
50% faster test sequencing and 40% lower installation costs than conventional solutions—with dual-function capability in a sub-55kg package.
Time Savings: Simultaneous voltage/PD measurements reduce test duration by 50%
Cost Efficiency: 60% lower shipping costs due to lightweight design
Safety Enhancement: Reduced weight minimizes rigging risks during installation
Future-Proof: Compatible with all major PD testers and voltmeters