100kv ~ 200kV Range
LQHVF 200kV/10000pF: Ultra-Precision Capacitive Divider
Industry-Leading Precision for Critical HV Measurement
The LQHVF 200kV/10000pF capacitive divider sets new standards in high-voltage measurement with its unprecedented combination of 10000pF capacity, ≤2pC partial discharge, and ≤0.2% dielectric loss. Engineered for 50Hz power systems, this solution delivers ±1% accuracy with a precision 2000:1 voltage ratio for the most demanding testing applications.
"The highest-capacity precision divider available - delivering laboratory-grade measurement with ≤2pC partial discharge at 200kV for critical diagnostics."
Technical Specifications
Parameter | Specification |
---|---|
Rated Voltage | 200kV |
Frequency | 50Hz |
Nominal Capacity | 10,000pF |
Voltage Ratio | 2000:1 |
Partial Discharge (PD) | ≤2pC at rated voltage |
Dielectric Loss (tanδ) | ≤0.2% |
Accuracy | ≤ ±1% |
Continuous Operation | 60 minutes at 100% rated voltage |
Insulation Withstand | 220kV (110% rated) for 1 minute |
Cooling System | ONAN (Oil Natural Air Natural) |
Breakthrough Precision Technologies
Ultra-Low Partial Discharge
Advanced electrode design and oil purification ensure ≤2pC at full 200kV operation
Exceptional Dielectric Properties
≤0.2% loss minimizes measurement error and energy dissipation
High-Resolution Measurement
2000:1 ratio provides 2x finer resolution than standard dividers
Advanced Structural Design
Removable Corona Rings
Aluminum alloy construction for transport efficiency
Stable Pedestal Base
Vibration-damped platform for measurement stability
Oil-Immersed Core
Mineral oil insulation with ONAN cooling
Corona-Free HV Connection
Scalable terminals prevent discharge at high voltages
Flexible Measurement Configurations
Single-Stage Measurement
Direct connection via shielded lead-wire
Two-Stage Series
Cascaded configuration for enhanced accuracy
Variable Frequency Operation
Compatible with resonant test systems
Performance Comparison
Feature | LQHVF 200kV/10000pF | Standard 200kV Dividers |
---|---|---|
Capacitance | 10,000pF | 1,000-5,000pF |
Partial Discharge | ≤2pC | 5-15pC |
Dielectric Loss | ≤0.2% | 0.5-1.0% |
Voltage Ratio | 2000:1 | 1000:1 |
Withstand Capability | 220kV/1min | 200-210kV |
Key Advantages
Unmatched Signal Integrity
10,000pF capacity provides superior noise rejection
Micro-Discharge Detection
≤2pC PD enables early insulation defect identification
Measurement Precision
2000:1 ratio delivers high-resolution voltage data
Thermal Stability
ONAN cooling maintains performance during extended tests
Critical Applications
Transformer Diagnostics
Precision dielectric loss and PD measurement
HV Cable Testing
Partial discharge mapping of transmission cables
Generator Stator Testing
Slot discharge detection in turbine generators
Calibration Laboratories
Reference standard for HV measurement systems
Research & Development
Dielectric material studies at 200kV
Medical Equipment
Testing of high-voltage X-ray generators
Operational Benefits
Enables detection of insulation defects 6-12 months earlier than conventional systems - preventing catastrophic failures in critical assets.
Predictive Maintenance: ≤2pC sensitivity identifies micro-discharges before visible damage
Reduced Downtime: Prevent unexpected failures in essential infrastructure
Enhanced Safety: 220kV withstand capability exceeds standard requirements
Data Accuracy: ≤0.2% dielectric loss ensures measurement integrity
Cost Efficiency: Single solution replaces multiple measurement devices
Compliance & Standards
Partial Discharge
IEC 60270 • IEEE 4
High-Voltage Testing
IEC 60060 • IEC 61869-11
Measurement Accuracy
IEEE C57.13 • ISO/IEC 17025
Safety Standards
IEC 61010 • EN 50191
Why Choose This Precision Divider?
The LQHVF 200kV/10000pF represents the pinnacle of high-voltage measurement technology. Its industry-leading 10,000pF capacity provides exceptional signal-to-noise ratio in electrically noisy environments, while the ≤2pC partial discharge performance enables early detection of insulation degradation. The precision 2000:1 voltage ratio delivers high-resolution measurement data, and the ≤0.2% dielectric loss ensures minimal measurement error. With its 220kV withstand capability and ONAN cooling system, the divider maintains stability during demanding 60-minute tests. The removable aluminum corona rings and base optimize transport and storage, and the flexible connection system supports both single-stage and two-stage configurations. Certified to international standards including IEC 60270 and IEEE 4, this solution is essential for utilities, high-voltage laboratories, and critical infrastructure monitoring where measurement precision is non-negotiable.