>800kV Range
LQHVF 1500kV/1500pF Capacitive Voltage Divider for 50Hz Power Networks
Engineered for extra-high-voltage measurement in 50Hz power systems, the LQHVF series delivers laboratory-grade precision in field applications. With dual-stage operation (500kV single/1500kV series) and ≤5pC partial discharge, it sets new standards for grid safety monitoring.
Technical Specifications
Parameter | Specification | Performance Advantage |
---|---|---|
Rated System Voltage | 1500kV (Two-Stage) | Covers ultra-HV transmission up to 765kV+ |
Single-Stage Voltage | 500kV Modular | Flexible configuration for substations |
Capacitance | 1500pF (System) 5250pF (Single-Stage) | Enhanced signal fidelity for 50Hz networks |
Frequency | 50Hz ±2% | Optimized for European/Asian power grids |
Partial Discharge | ≤5pC @ 100% voltage | Early fault detection capability |
Dielectric Loss | <0.3% | Industry-leading efficiency (IEC 60247) |
Insulation Test | 110% rated voltage for 1min | Exceeds IEC 60060-1 requirements |
Dual-Stage Operation System
Single-Stage Configuration
Voltage: 500kV operational
Capacitance: 5250pF
Applications:
Substation busbar monitoring
Generator step-up transformer testing
Two-Stage Series Configuration
Voltage: 1500kV operational
Capacitance: 1500pF
Applications:
HVDC converter station measurement
Transmission line commissioning
Advanced Engineering Features
ONAN Cooling Technology
Oil-Natural Air-Natural circulation maintains thermal stability at 50Hz continuous operationCorona-Free Design
Precision-machined aluminum alloy rings eliminate discharge above 400kVModular Pedestal System
Removable base with seismic-grade stabilityQuick-connect HV corona-free terminals
Integrated vibration dampers
Smart Measurement Interface
Shielded lead-wire connection to variable frequency sources (45-55Hz range)
Safety & Compliance
Double insulation barrier design
IEC 61869-11:2018 certified (Capacitive Voltage Transformers)
Partial discharge testing per IEC 60270:2015
Automatic dielectric recovery after overvoltage events
Industrial Applications
Power Grid Monitoring: Real-time voltage measurement in 380kV+ transmission networks
Factory Acceptance Testing: Partial discharge validation for GIS systems
Research Applications: Power quality analysis at 50Hz fundamental frequency
Renewable Integration: Offshore wind farm step-up transformer monitoring
Operational Guidelines
Deploy in ambient temperatures <45°C (derating required above)
Annual dielectric loss testing per IEEE C57.152
Transport with factory-supplied anti-corona packaging
Verify phase-to-ground clearance ≥5 meters
Technical Innovation: The optimized 1500pF capacitance reduces phase error by 40% compared to conventional dividers at 50Hz, enabling precise power factor measurement in critical infrastructure.