>800kV Range
LQHVF 1250kV/500pF Capacitor Voltage Divider: Advanced ONAN-Cooled Design
Engineered for precision high-voltage measurement with industry-leading thermal management and PD performance
Technical Specifications
Parameter | Specification |
---|---|
Rated Voltage | 1250kV AC |
Nominal Capacitance | 500pF ±5% |
Voltage Ratio | 4000:1 |
Frequency | 50Hz |
Dielectric Loss (tanδ) | <0.2% @ 20°C |
Cooling System | ONAN (Oil Natural Air Natural) |
Temperature Coefficient | 5 × 10-5 %/°C |
PD Level | <5pC @ 1250kV <3pC @ 1000kV (80% rated) |
Insulation Level | 1375kV/1 min |
Accuracy | ≤±1% |
Continuous Operation | 60 mins @ 100% rated voltage |
Breakthrough Engineering Features
◉ ONAN Cooling Technology
Passive thermal management system:
• Natural oil convection + air cooling
• Maintains dielectric stability during 60-min operations
• Eliminates need for forced cooling systems
◉ Ultra-Low PD Performance
Industry-leading partial discharge levels:
• <5pC at full 1250kV rating
• <3pC at 1000kV (transformer-verified)
• Exceeds IEC 60270 Class I requirements
◉ Modular Removable Design
Field-configurable components:
• Interchangeable corona rings
• Detachable HV/LV arms
• Removable base for transformer integration
• 50% faster deployment than fixed units
Structural Advantages
Optimized Oil-Immersed Construction
Dielectric fluid: Premium insulating oil (IEC 60296)
Hermetic sealing prevents moisture ingress
Corona shield design minimizes surface discharges
Thermal Stability System
Low TCR dielectric materials (5×10-5%/°C)
ONAN cooling maintains oil temp ≤50°C @ full load
Homogeneous media prevents thermal stratification
"ONAN-cooled HV dividers demonstrate 40% lower thermal drift than forced-cooled systems in ambient temperatures above 35°C." - Journal of High Voltage Engineering
Certified Test Applications
▶ Extended Duration HV Testing
60-min continuous operation at:
• 1250kV full rating
• 100% design current
• Ambient temps up to 40°C
▶ Critical PD Detection
Ultra-sensitive measurement for:
• Power transformer diagnostics
• GIS partial discharge mapping
• Cable termination assessments
▶ Field Deployment
Removable design enables:
• Substation commissioning
• Mobile test lab operations
• On-site factory acceptance tests
Global Compliance & Safety
IEC 60270: Partial discharge measurements
IEC 60137: Bushings for alternating voltages
IEEE 4-2013: HV testing techniques
EN 60076: Power transformer standards
Operational Comparison
Feature | Standard Divider | LQHVF 1250kV/500pF |
---|---|---|
PD Level @ 1000kV | 10-15pC | <3pC |
Thermal Drift | 20×10-5/°C | 5×10-5/°C |
Cooling Requirement | Forced air/oil | Passive ONAN |