100kv ~ 200kV Range
LQHVF 130kV/3000pF Wide-Frequency Capacitive Voltage Divider
Advanced measurement solution featuring unique epoxy tube construction with oil-paper insulation and wide 20-300Hz frequency response. Engineered for resonant testing systems, power quality analysis, and specialized industrial applications.
Technical Specifications
Rated Voltage: 130kV AC RMS
Nominal Capacitance: 3000pF
Dividing Ratio: 1500:1 (±1.5% accuracy)
Frequency Range: 20-300Hz (full accuracy)
Dielectric Loss: ≤0.5% @ 25°C
Insulation Withstand: 143kV/1min (110% rated voltage)
Operating Duration: 60 minutes continuous @ 100% voltage
Cooling System: ONAN (Oil Natural Air Natural)
Phase Configuration: Single phase
Advanced Structural Design
Epoxy Tube Construction
Oil-Paper Insulation: Superior dielectric properties for stable performance
Epoxy Shell: High mechanical strength with excellent tracking resistance
Modular Design: Field-replaceable components reduce downtime
Optimized Components
Aluminum Corona Rings: Lightweight alloy for transport efficiency
Removable Pedestal: Heavy-duty base with vibration damping
Scalable HV Connections: Corona-free terminals for flexible configurations
Performance Validation
Parameter | Test Standard | Performance |
---|---|---|
Frequency Response | IEC 60060-1 | ±1.2% deviation 20-300Hz |
Voltage Withstand | IEC 60060-1 | 143kV/1min (110% rated) |
Temperature Stability | IEC 60270 | ±0.4% capacitance shift (-20°C to +50°C) |
Phase Accuracy | IEC 61869-11 | <5 minutes at 50Hz |
Compliance: Includes certified measurement report for 1500:1 ratio.
Specialized Applications
Resonant Testing Systems
Transformer frequency response analysis
High-voltage cable testing
GIS (Gas-Insulated Switchgear) commissioning
Power Quality Analysis
Sub-harmonic measurement
Voltage flicker analysis
Transient overvoltage capture
Industrial Research
Power electronics prototype testing
Medium-frequency transformer research
Renewable energy converter validation
Operational Advantages
Wide Frequency Response: 20-300Hz range for specialized testing
High Ratio Accuracy: 1500:1 division for detailed measurements
Robust Construction: Epoxy tube with oil-paper insulation ensures reliability
Thermal Management: ONAN cooling maintains stability
Maintenance Optimized: Removable base enables field servicing
Electrical Integration
Connection Protocol
Establish dual 35mm² ground connections to earth grid
Connect special measuring lead-wire to variable frequency source (20-300Hz)
Configure for single-stage or dual-stage operation
Implement corona-free HV connections
Perform step-test (20%, 50%, 80%, 100%)
Measurement Configurations
Single-Stage Mode: Standard 1500:1 division
Dual-Stage Series Mode: Extended range for precision applications
Frequency-Specific Calibration: Optional calibration at key frequencies
Safety & Maintenance
Critical Procedures
Pre-Operation Check: Verify insulation integrity and grounding
Frequency Ramp Rate: Max 50Hz/second when testing below 50Hz
Thermal Monitoring: Required during extended low-frequency operation
Discharge Protocol: 10-minute discharge after full-load operation
Maintenance Schedule
Interval | Procedure |
---|---|
Quarterly | Insulation resistance test |
Biannually | Dielectric absorption ratio verification |
Annually | Full ratio accuracy calibration |