High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

100kv ~ 200kV Range

LQHVF 130kV/3000pF Wide-Frequency Voltage Divider | 20-300Hz Precision Measurement

Precision 130kV/3000pF capacitive voltage divider with 20-300Hz frequency range and 1500:1 ratio. Features epoxy tube construction, oil-paper insulation, and removable base for versatile high-voltage testing.


  • US$ 4,099.00
  • Lead time: 30 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHVF 130kV/3000pF Wide-Frequency Capacitive Voltage Divider

Advanced measurement solution featuring unique epoxy tube construction with oil-paper insulation and wide 20-300Hz frequency response. Engineered for resonant testing systems, power quality analysis, and specialized industrial applications.

Technical Specifications

  • Rated Voltage: 130kV AC RMS

  • Nominal Capacitance: 3000pF

  • Dividing Ratio: 1500:1 (±1.5% accuracy)

  • Frequency Range: 20-300Hz (full accuracy)

  • Dielectric Loss: ≤0.5% @ 25°C

  • Insulation Withstand: 143kV/1min (110% rated voltage)

  • Operating Duration: 60 minutes continuous @ 100% voltage

  • Cooling System: ONAN (Oil Natural Air Natural)

  • Phase Configuration: Single phase

Advanced Structural Design

Epoxy Tube Construction

  • Oil-Paper Insulation: Superior dielectric properties for stable performance

  • Epoxy Shell: High mechanical strength with excellent tracking resistance

  • Modular Design: Field-replaceable components reduce downtime

Optimized Components

  • Aluminum Corona Rings: Lightweight alloy for transport efficiency

  • Removable Pedestal: Heavy-duty base with vibration damping

  • Scalable HV Connections: Corona-free terminals for flexible configurations

Performance Validation

ParameterTest StandardPerformance
Frequency ResponseIEC 60060-1±1.2% deviation 20-300Hz
Voltage WithstandIEC 60060-1143kV/1min (110% rated)
Temperature StabilityIEC 60270±0.4% capacitance shift (-20°C to +50°C)
Phase AccuracyIEC 61869-11<5 minutes at 50Hz

Compliance: Includes certified measurement report for 1500:1 ratio.

Specialized Applications

Resonant Testing Systems

  • Transformer frequency response analysis

  • High-voltage cable testing

  • GIS (Gas-Insulated Switchgear) commissioning

Power Quality Analysis

  • Sub-harmonic measurement

  • Voltage flicker analysis

  • Transient overvoltage capture

Industrial Research

  • Power electronics prototype testing

  • Medium-frequency transformer research

  • Renewable energy converter validation

Operational Advantages

  • Wide Frequency Response: 20-300Hz range for specialized testing

  • High Ratio Accuracy: 1500:1 division for detailed measurements

  • Robust Construction: Epoxy tube with oil-paper insulation ensures reliability

  • Thermal Management: ONAN cooling maintains stability

  • Maintenance Optimized: Removable base enables field servicing

Electrical Integration

Connection Protocol

  1. Establish dual 35mm² ground connections to earth grid

  2. Connect special measuring lead-wire to variable frequency source (20-300Hz)

  3. Configure for single-stage or dual-stage operation

  4. Implement corona-free HV connections

  5. Perform step-test (20%, 50%, 80%, 100%)

Measurement Configurations

  • Single-Stage Mode: Standard 1500:1 division

  • Dual-Stage Series Mode: Extended range for precision applications

  • Frequency-Specific Calibration: Optional calibration at key frequencies

Safety & Maintenance

Critical Procedures

  • Pre-Operation Check: Verify insulation integrity and grounding

  • Frequency Ramp Rate: Max 50Hz/second when testing below 50Hz

  • Thermal Monitoring: Required during extended low-frequency operation

  • Discharge Protocol: 10-minute discharge after full-load operation

Maintenance Schedule

IntervalProcedure
QuarterlyInsulation resistance test
BiannuallyDielectric absorption ratio verification
AnnuallyFull ratio accuracy calibration