100kv ~ 200kV Range
LQHVF 120kV/4000pF Capacitive Voltage Divider & Coupling Capacitor
High-current dual-function solution combining precision voltage measurement with power system coupling capabilities. Features 10A current capacity and 12nF overall capacitance for demanding industrial applications in power transmission, renewable energy, and heavy electrical testing.
Technical Specifications
Rated Voltage: 120kV AC RMS
Nominal Capacitance: 4000pF (per unit)
Overall Capacitance: 12nF (system total)
Rated Current: 10A continuous
Dividing Ratio: 2000:1 (±1% accuracy)
Frequency: 50Hz (40-500Hz optional)
Dielectric Loss: <0.2% @ 25°C
Partial Discharge: <3pC at 120kV
Insulation Withstand: 132kV/1min (110% rated voltage)
Operating Duration: Continuous @ 100% rated current
Cooling System: ONAN (Oil Natural Air Natural)
High-Current Structural Design
Industrial-Grade Construction
Aluminum Corona Rings: Optimized alloy for thermal management at 10A load
Removable Pedestal: Heavy-duty base with quick-release maintenance access
Scalable HV Connections: Corona-free terminals rated for 10A continuous
Multi-Unit Configuration: Three 4000pF units deliver 12nF overall capacitance
Measurement System
Special Measuring Lead-Wire: 10A-rated interface with variable frequency sources
Dual-Stage Operation: Single-stage or series configurations
High-Resolution Ratio: 2000:1 division for precision measurements
Performance Validation
Parameter | Test Standard | Performance |
---|---|---|
Current Capacity | IEC 60137 | 12A continuous @ 120kV |
Partial Discharge | IEC 60270 | <2.5pC @ 120kV |
Temperature Rise | IEEE C57.19.00 | 38°C above ambient @ 10A load |
Voltage Coefficient | IEC 60060-1 | <0.02%/kV |
Compliance: Meets IEC 61869-11, IEEE C57.13, and ANSI/NETA MTS-2023 standards.
Industrial Applications
Power Transmission
EHV substation busbar monitoring
Transformer diagnostic testing
High-current switchgear validation
Renewable Energy
Solar farm central inverter monitoring
Wind turbine step-up transformers
Battery storage system integration
Industrial Processes
Electrolytic manufacturing systems
Industrial furnace power monitoring
High-power motor drive testing
Operational Advantages
High-Current Capacity: 10A continuous rating for demanding applications
Dual-Function Design: Combines voltage division and coupling capabilities
Scalable Capacitance: 12nF overall capacity through multi-unit configuration
Precision Measurement: 2000:1 ratio enables detailed voltage analysis
Thermal Management: ONAN cooling maintains stability at full load
Electrical Integration
Connection Methodology
Configure units in parallel for 12nF/10A capacity
Establish dual 50mm² ground connections to earth grid
Connect special 10A-rated lead-wire to variable frequency source
Implement HV corona-free connections
Select single-stage or dual-stage measurement mode
Current Handling Specifications
Parameter | Value |
---|---|
Continuous Current | 10A @ 50Hz |
Short-Term Overload | 15A for 10 minutes |
Connection Resistance | <0.5mΩ per terminal |
Safety & Maintenance
Critical Procedures
Pre-Operation Check: Verify oil level and grounding integrity
Current Monitoring: Continuous amperage tracking during operation
Thermal Supervision: IR monitoring of connections at >5A loads
Discharge Protocol: 15-minute discharge after full-load operation
Maintenance Schedule
Interval | Procedure |
---|---|
Monthly | Connection resistance measurement |
Quarterly | Dielectric fluid analysis |
Biannually | Current calibration verification |
Annually | Full system recertification |