100kv ~ 200kV Range
LQHVF 120kV/33000pF Coupling Capacitor & Capacitive Voltage Divider
Industry-leading precision instrument featuring unmatched<1pc partial="" discharge="" performance="" and="" 33nf="" capacity.="" engineered="" for="" critical="" applications="" in="" national="" laboratories="">
Technical Specifications
Rated Voltage: 120kV AC RMS
Nominal Capacitance: 33,000pF (33nF)
Configuration: Single-stage design
Frequency: 50Hz (30-300Hz optional)
Dielectric Loss: <0.2% @ 25°C
Partial Discharge: <1pC at 120kV (industry record)
Measuring Accuracy: ≤±1%
Operating Duration: 60 minutes continuous @ 100% rated voltage
Cooling System: ONAN (Oil Natural Air Natural)
Dimensions: Base Ø300mm / Top Ø400mm × 1650mm height
Weight: 300kg (approximate)
Precision Structural Design
Ultra-Low PD Architecture
Triple Corona Rings: Aerospace-grade aluminum alloy for perfect field grading
Removable Pedestal: Heavy-duty base with vibration damping
Vacuum-Impregnated Windings: Eliminates micro-voids for PD suppression
Gold-Plated Interfaces: Minimize contact resistance in LV measurement arms
Measurement System
Special Measuring Lead-Wire: Double-shielded for EMI immunity
Corona-Free HV Connection: Multi-stage grading for zero discharge
Scalable Configuration: Supports single-stage and dual-stage operation
Performance Validation
Parameter | Test Standard | Performance |
---|---|---|
Partial Discharge | IEC 60270 | <0.8pC @ 120kV |
Voltage Coefficient | IEC 60060-1 | <0.015%/kV |
Temperature Stability | IEC 60270 | ±0.1% capacitance shift (-30°C to +60°C) |
Phase Error | IEC 61869-11 | <1 minute at 50Hz |
Compliance: Exceeds IEC 61869-11, IEEE C57.13, and ANSI/NETA MTS-2023 standards.
Elite Applications
National Metrology
Primary voltage standards
Reference dividers for calibration
International measurement comparisons
Ultra-High Voltage Research
Particle accelerator power systems
Fusion energy experiments
Plasma physics facilities
Spacecraft power system testing
Critical Infrastructure
Nuclear power plant monitoring
HVDC converter station diagnostics
National grid reference measurements
Operational Advantages
Unmatched PD Performance: <1pC enables measurements impossible with conventional dividers
Ultra-High Capacitance: 33nF capacity for energy-intensive systems
Metrological Precision: <0.015%/kV voltage coefficient for reference-grade accuracy
Thermal Stability: ±0.1% capacitance shift across extreme temperatures
Future-Proof Design: Scalable for next-generation HV research
Installation & Integration
Laboratory Requirements
Foundation: Vibration-isolated concrete base ≥0.5m³
EMI Shielding: Faraday cage recommended for pC-level measurements
Environmental Control: 25°C ±1°C for metrological work
Clearance: 3m radial clearance at full voltage
Connection Protocol
Install quad 50mm² ground cables to dedicated earth pit
Connect double-shielded lead-wire to measurement system
Implement multi-stage corona-free HV connections
Establish NIST-traceable calibration reference
Execute 7-step verification (10-100% in 15% increments)
Calibration & Maintenance
Metrological Procedures
Interval | Procedure | Standard |
---|---|---|
Monthly | Partial discharge baseline verification | IEC 60270 |
Quarterly | Capacitance stability test | IEC 61869-11 |
Biannually | Full ratio accuracy calibration | ISO/IEC 17025 |
Annually | Comprehensive performance validation | NIST HB 150 |
Note: Includes on-site verification by metrology engineers