100kv ~ 200kV Range
LQHVF 120kV/12000pF Capacitive Voltage Divider
Robust high-voltage measurement solution featuring 12nF capacitance and dual-stage operation. Engineered for precision in industrial power testing, substation monitoring, and high-voltage research applications.
Technical Specifications
Rated Voltage: 120kV AC RMS
Nominal Capacitance: 12,000pF (12nF)
Dividing Ratio: 1000:1 (±1% accuracy)
Frequency: 60Hz (50-400Hz optional)
Dielectric Loss: <0.2% @ 25°C
Insulation Withstand: 132kV/1min (110% rated voltage)
Cooling System: ONAN (Oil Natural Air Natural)
Operating Duration: 60 minutes continuous @ 100% voltage
Industrial Structural Design
Optimized Construction
Aluminum Corona Rings: Lightweight alloy reduces shipping costs while preventing corona discharge
Removable Pedestal: Heavy-duty cast base with quick-release maintenance access
Scalable HV Connections: Corona-free terminals support multiple configurations
Oil-Immersed Design: Mineral oil insulation for thermal stability
Measurement System
Special Measuring Lead-Wire: Direct interface with 50-400Hz variable frequency sources
Dual-Stage Operation: Single-stage or series configurations for flexible testing
Corona-Free HV Connection: Prevents measurement interference at high voltages
Performance Validation
Parameter | Test Standard | Performance |
---|---|---|
Voltage Withstand | IEC 60060-1 | 132kV/1min (110% rated) |
Capacitance Stability | IEC 60270 | ±0.7% from 10-100% voltage |
Temperature Rise | IEEE C57.19.00 | 34°C above ambient @ full load |
Phase Error | IEC 61869-11 | <3 minutes at 60Hz |
Compliance: Meets IEC 61869-11, IEEE C57.13, and ANSI/NETA MTS-2023 standards.
Industrial Applications
Power Transmission
EHV substation monitoring
Transformer diagnostic testing
Switchgear commissioning
Industrial Testing
High-power motor testing
Generator step-up system validation
Industrial furnace power systems
Energy Research
Renewable energy converter testing
Power electronics validation
Capacitive energy storage analysis
Operational Advantages
High-Capacity Performance: 12,000pF capacitance for energy-intensive applications
Measurement Flexibility: Dual-stage configuration for versatile test setups
Thermal Management: ONAN cooling ensures stability during extended operation
Maintenance Optimized: Removable base enables field servicing
Transport Efficient: Aluminum components reduce shipping costs
Installation & Integration
Foundation Requirements
Base Area: Minimum 0.3m² reinforced concrete
Anchoring: Four M16 anchor bolts
Clearance: 2.5m radial clearance at full voltage
Electrical Connection Protocol
Establish dual 35mm² ground cables to earth grid
Connect special measuring lead-wire to variable frequency source
Configure for single-stage or dual-stage operation
Implement corona-free HV connections
Perform step-test at 25%, 50%, 75%, 100% voltage
Safety & Maintenance
Critical Procedures
Pre-Operation Check: Verify oil level and grounding integrity
Thermal Monitoring: Continuous temperature tracking during operation
Discharge Protocol: 10-minute discharge time after operation
Preventive Maintenance: Annual dielectric fluid analysis
Calibration Schedule
Interval | Procedure |
---|---|
Quarterly | Ratio accuracy verification |
Biannually | Capacitance stability test |
Annually | Full calibration and certification |