100kv ~ 200kV Range
LQHVF 100kV/1000pF Coupling Capacitor & Capacitive Voltage Divider
Ultra-compact dual-function solution delivering laboratory-grade precision in a portable package. Combines coupling capacitor functionality with voltage division capability for versatile 100kV measurements at<30kg weight.="">
Technical Specifications
Rated Voltage: 100kV AC RMS
Nominal Capacitance: 1000pF
Dividing Ratio: 1000:1 (±1% accuracy)
Frequency: 50/60Hz (45-500Hz optional)
Dielectric Loss: <0.5% @ 25°C
Partial Discharge: <2pC at 100kV
Cooling System: ONAN (Oil Natural Air Natural)
Operating Duration:
60 minutes continuous @ 100% rated voltage
Continuous operation @ 80% rated voltage
Dimensions: Base Ø150mm / Top Ø500mm × 1200mm height
Weight: <30kg
Compact Structural Design
Modular Oil-Immersed Architecture
Removable Base: Enables field maintenance without specialized tools
Corona Rings: Dual aluminum alloy rings prevent discharge
LY Arm: Low-voltage interface with shielded BNC connectors
HV Arm: Precision capacitive stack with field-grading design
Space-Optimized: 30% more compact than comparable 100kV dividers
Portability Features
Integrated Carrying Handles: Ergonomically positioned for single-person transport
Quick-Disconnect Components: Field-ready in <8 minutes
Tripod-Compatible Base: Standard 3/8"-16 mounting thread
Performance Validation
Parameter | Test Standard | Performance |
---|---|---|
Voltage Withstand | IEC 60060-1 | 120kV/1min (120% rated) |
Partial Discharge | IEC 60270 | <1.8pC @ 100kV |
Temperature Rise | IEEE C57.19.00 | 38°C above ambient @ full load |
Vibration Resistance | IEC 60068-2-6 | 7g @ 10-150Hz |
Compliance: Exceeds IEC 61869-11, IEEE C57.13, and ANSI/NETA MTS-2023 standards.
Dual-Function Applications
Field Testing
Mobile substation diagnostics
Cable termination verification
Transformer ratio testing
Rotating machinery insulation checks
Laboratory Research
Partial discharge studies
Dielectric material characterization
HV component R&D validation
Calibration reference standard
Renewable Energy
Solar farm combiner monitoring
Wind turbine step-up transformers
Battery isolation testing
Power converter validation
Operational Advantages
Ultra-Low PD: <2pC ensures precision in sensitive measurements
Portability Optimized: <30kg weight with compact footprint
Dual-Function Design: Functions as both coupling capacitor and voltage divider
Thermal Management: ONAN cooling maintains stability during extended tests
Maintenance Simplified: Removable base enables field servicing
Field Deployment Protocol
Rapid Setup Procedure
Position unit on stable surface/tripod
Attach corona rings and connect arms
Establish dual-point ground connection
Connect LV measurement leads to test set
Implement HV corona-free connection
Perform step-test (20%, 50%, 80%, 100%)
Transportation Guidelines
Maximum Tilt: 30° during transit
Temperature Limits: -25°C to +55°C
Shock Protection: Use included foam inserts
Packaged Weight: 34kg (with transit case)
Safety & Maintenance
Critical Safety Procedures
Establish 2.5m safety perimeter per IEEE 516
Wear Class 4 arc-flash protection at full voltage
Verify grounding continuity (≤0.1Ω resistance)
Check dielectric fluid level before operation
Maintenance Schedule
Interval | Procedure | Standard |
---|---|---|
After each use | Visual inspection for damage | ANSI/NETA ETS |
Quarterly | Dielectric fluid integrity test | IEC 60480 |
Annually | Full calibration and certification | ISO/IEC 17025 |