High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

>800kV Range

LQHVF 1000kV/5000pF Dual-Unit Voltage Divider | High-Capacity HV Measurement

1000kV/5000pF capacitive voltage divider with dual-unit serial design. Features ≤3pC partial discharge, ONAN cooling, and 3000:1 ratio for precision high-voltage testing applications.


  • US$ 21,689.00
  • Lead time: 45 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHVF 1000kV/5000pF Dual-Unit Capacitive Voltage Divider & Coupling Capacitor

High-Capacity Solution for Ultra-High Voltage Measurement

The LQHVF 1000kV/5000pF features an innovative dual-unit serial design engineered for precision measurements in extreme voltage environments. With its exceptional ≤3pC partial discharge performance at 800kV and robust ONAN cooling system, this dual-function device delivers laboratory-grade accuracy for critical power transmission testing and certification applications.

Technical Specifications

ParameterSpecificationTesting Standard
System Configuration2 × 500kV units in seriesIEC 61869-11
Rated Voltage1000kV ACIEC 60137
Unit Capacitance10,000pF per unitIEC 61869-11
System Capacitance5,000pF
Frequency50HzIEEE C57.13
Partial Discharge (100% VR)≤5pCIEC 60270
Partial Discharge (80% VR)≤3pC
Dividing Ratio3000:1IEC 60044-7
Accuracy Class≤±1%Class 0.5
Dielectric Loss<0.2%ASTM D924
Insulation Withstand1100kV/1min (110% VR)IEC 60060
Cooling SystemONAN (Oil Natural Air Natural)IEC 60076-2

Dual-Unit Serial Design Advantages

Modular Configuration

Two 500kV/10,000pF units in series:

  • Each unit independently testable

  • System capacitance: 5,000pF

  • Flexible deployment options


Advanced Corona Control

Aluminum alloy corona rings:

  • Ensure corona-free operation

  • Optimized for transportation

  • Scalable HV connections


Measurement Flexibility

Versatile connection options:

  • Special lead-wire to variable frequency sources

  • Single-stage and two-stage configurations

  • HV corona-free connections


Robust Foundation

Removable pedestal:

  • Provides exceptional stability

  • Enables rapid assembly/disassembly

  • Adapts to various test environments


Performance Comparison

ParameterStandard 1000kV DividersLQHVF Dual-Unit SystemImprovement
Partial Discharge @ 80% VR5-8pC≤3pC40-60% reduction
Transportation Weight800-1000kgModular 500kg units50% easier handling
Deployment Time6-8 hours3-4 hours50% faster
Measurement FlexibilitySingle configurationDual-configuration options2x application versatility

Partial Discharge Performance

PD Levels vs. Applied Voltage

Voltage (% of Rated)Max PD LevelTest Conditions
50% (500kV)≤2pCIEC 60270 Method
80% (800kV)≤3pCFull system test
100% (1000kV)≤5pCContinuous 1-hour operation
110% (1100kV)No discharge1-minute withstand test

Testing Methodology

  • PD measurements comply with IEC 60270 standards

  • Tests performed at 50Hz with variable frequency power source

  • Background noise <1pC during all measurements

  • ONAN cooling maintained throughout testing

Industrial Applications

Power Transformer Testing

Impulse withstand and PD measurement per IEC 60076

HVDC Converter Stations

Voltage monitoring in ultra-high voltage transmission systems

High-Power Laboratories

Reference standard for calibrating 800kV+ test systems

Research & Development

Dielectric strength testing of new insulation materials

Compliance & Certifications

  • IEC 61869-11: Instrument Transformers

  • IEC 60060-1: High-voltage test techniques

  • IEEE 4-2013: Standard for HV Testing

  • EN 50191: Erection and operation of test facilities

  • ASTM D924: Standard Test Method for Dissipation Factor

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message