>800kV Range
LQHVF 1000kV/5000pF Dual-Unit Capacitive Voltage Divider & Coupling Capacitor
High-Capacity Solution for Ultra-High Voltage Measurement
The LQHVF 1000kV/5000pF features an innovative dual-unit serial design engineered for precision measurements in extreme voltage environments. With its exceptional ≤3pC partial discharge performance at 800kV and robust ONAN cooling system, this dual-function device delivers laboratory-grade accuracy for critical power transmission testing and certification applications.
Technical Specifications
Parameter | Specification | Testing Standard |
---|---|---|
System Configuration | 2 × 500kV units in series | IEC 61869-11 |
Rated Voltage | 1000kV AC | IEC 60137 |
Unit Capacitance | 10,000pF per unit | IEC 61869-11 |
System Capacitance | 5,000pF | |
Frequency | 50Hz | IEEE C57.13 |
Partial Discharge (100% VR) | ≤5pC | IEC 60270 |
Partial Discharge (80% VR) | ≤3pC | |
Dividing Ratio | 3000:1 | IEC 60044-7 |
Accuracy Class | ≤±1% | Class 0.5 |
Dielectric Loss | <0.2% | ASTM D924 |
Insulation Withstand | 1100kV/1min (110% VR) | IEC 60060 |
Cooling System | ONAN (Oil Natural Air Natural) | IEC 60076-2 |
Dual-Unit Serial Design Advantages
Modular Configuration
Two 500kV/10,000pF units in series:
Each unit independently testable
System capacitance: 5,000pF
Flexible deployment options
Advanced Corona Control
Aluminum alloy corona rings:
Ensure corona-free operation
Optimized for transportation
Scalable HV connections
Measurement Flexibility
Versatile connection options:
Special lead-wire to variable frequency sources
Single-stage and two-stage configurations
HV corona-free connections
Robust Foundation
Removable pedestal:
Provides exceptional stability
Enables rapid assembly/disassembly
Adapts to various test environments
Performance Comparison
Parameter | Standard 1000kV Dividers | LQHVF Dual-Unit System | Improvement |
---|---|---|---|
Partial Discharge @ 80% VR | 5-8pC | ≤3pC | 40-60% reduction |
Transportation Weight | 800-1000kg | Modular 500kg units | 50% easier handling |
Deployment Time | 6-8 hours | 3-4 hours | 50% faster |
Measurement Flexibility | Single configuration | Dual-configuration options | 2x application versatility |
Partial Discharge Performance
PD Levels vs. Applied Voltage
Voltage (% of Rated) | Max PD Level | Test Conditions |
---|---|---|
50% (500kV) | ≤2pC | IEC 60270 Method |
80% (800kV) | ≤3pC | Full system test |
100% (1000kV) | ≤5pC | Continuous 1-hour operation |
110% (1100kV) | No discharge | 1-minute withstand test |
Testing Methodology
PD measurements comply with IEC 60270 standards
Tests performed at 50Hz with variable frequency power source
Background noise <1pC during all measurements
ONAN cooling maintained throughout testing
Industrial Applications
Power Transformer Testing
Impulse withstand and PD measurement per IEC 60076
HVDC Converter Stations
Voltage monitoring in ultra-high voltage transmission systems
High-Power Laboratories
Reference standard for calibrating 800kV+ test systems
Research & Development
Dielectric strength testing of new insulation materials
Compliance & Certifications
IEC 61869-11: Instrument Transformers
IEC 60060-1: High-voltage test techniques
IEEE 4-2013: Standard for HV Testing
EN 50191: Erection and operation of test facilities
ASTM D924: Standard Test Method for Dissipation Factor