High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

Secondary Switchgear Cabinet

LQXGN2-10 Secondary HV Switchgear Cabinet: 12kV Distribution System Solution

Technical specifications for LQXGN2-10 secondary switchgear with 16kA vacuum contactors, 0.5-class instrument transformers, and manual switching for 10-12kV systems.


  • US$ 7,385.00
  • Lead time: 45 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQXGN2-10 Secondary HV Switchgear: Reliable 12kV Power Distribution

Structural Design

Based on KN28-1 standard cabinet with protective metallic mesh screens, this switchgear integrates:

  • Spring-operated vacuum contactors

  • Dual-winding instrument transformers

  • Manual close/open switching mechanism

  • Isolating switches with visible break points

System Specifications

ParameterValue
Rated Frequency50Hz
Protective FeaturesMetallic mesh barriers, visible isolation
Control MechanismManual operation + spring-assisted drive

Component Specifications

Vacuum Contactor

  • Rated Voltage: 12kV

  • Rated Current: 630A

  • Breaking Capacity: 16kA

  • Operating Mechanism: Spring

Voltage Transformer

  • Type: Casting Resin / Full Insulation

  • Rated Voltage: 10kV

  • Ratio: 10kV/100V/100V (dual secondary)

  • Accuracy Class: 0.5

Current Transformer

  • Type: Casting Resin

  • Rated Voltage: 10kV

  • Ratio: 100A/5A/5A (dual secondary)

  • Accuracy Class: 0.5

Auxiliary Switch

  • Rated Voltage: 12kV

  • Rated Current: 100A

Key Operational Features

  • Manual Switching: Local control via mechanical handle

  • Visible Isolation: Physical disconnection verification

  • Dual Instrumentation: Simultaneous metering & protection signals

  • Arc Containment: Metallic mesh prevents arc propagation

Industrial Applications

  • Factory Power Distribution: Main secondary switchgear for 10kV incomers

  • Renewable Energy Plants: Wind/solar farm collection substations

  • Mining Operations: Underground power distribution centers

  • Infrastructure Projects: Tunnel ventilation system power control

Safety & Compliance

Designed to IEC 62271-200 standards with:

  • Visible earthing points

  • Mechanical interlock between isolator and contactor

  • Dielectric strength tested at 28kV AC for 1min

Maintenance Protocols

  • Annual contact resistance measurement (<60μΩ)

  • 3-year timing test for spring mechanism

  • 5-year dielectric verification per IEC 60480

>>>WhatsApp Communication<<<