<100kVA Range
LQLVF 50KVA/2*142.9A Power Isolation & Noise Filter: Advanced Dual-Line Protection for Sensitive Equipment
Core Technical Specifications
Parameter | Specification |
---|---|
Model | LQLVF 50KVA/2*142.9A |
Configuration | Single Phase, Dual Line |
Rated Capacity | 50kVA |
Input/Output Voltage | 0.35kV |
Rated Current | 142.9A per Line |
Frequency Range | 45-65Hz |
Full-Load Operation | 60 minutes at 100% rating |
Advanced Performance Specifications
Attenuation:
40kHz-100kHz: >40dB
100kHz-1MHz: >60dB
Partial Discharge: <3pC (Ultra-low noise emission)
Insulation Withstand: >5kV for 1 minute (input/output)
Insertion Loss: <0.25dB across 45-65Hz
Isolation Resistance: >1GΩ at 500V DC
Dual-Line Isolation Technology
Galvanic Isolation: 4kV basic insulation between lines
Independent Noise Control: Separate EMI filtering for each power line
Ground Loop Prevention: Eliminates common-mode interference
Surge Protection: 10kV/μs transient response capability
Engineering Design Features
Wide-Frequency Reactors: Nanocrystalline cores for 45-65Hz operation
Triple-Shielded Isolation: Class-I insulation system
Low-PD Construction: Vacuum-encapsulated windings
Thermal Management: B-class insulation (130°C rating)
Critical Applications
Medical imaging equipment power isolation
Semiconductor fabrication tool power
Precision laboratory instrumentation
Aerospace test equipment power
Pharmaceutical manufacturing systems
"Combined isolation and filtering with <3pC PD levels is essential for sensitive equipment where ground loops and EMI can compromise microvolt-level measurements."
– Journal of Medical Engineering & Technology
Installation Guidelines
Mount on non-conductive surfaces using isolation bushings
Maintain 100mm clearance from grounded surfaces
Use 35mm² shielded twisted-pair cables
Implement isolated ground for each line (<0.05Ω resistance)
Verify insulation resistance before energization
Insulation Performance Validation
Test | Standard | Result |
---|---|---|
Dielectric Strength | IEC 60664-1 | >5kV/1min (input-output) |
Partial Discharge | IEC 60270 | <3pC at 1.5Ur |
Impulse Withstand | IEC 61000-4-5 | 6kV/3kA pass |
Creepage Distance | IEC 60950 | >12mm (Pollution Degree 2) |
Compliance & Standards
IEC 60601-1-2 (Medical EMC)
EN 55011 Class A (Industrial emissions)
ANSI/AAMI ES60601-1 (Medical safety)
IEC 61010-1 (Lab equipment safety)
Safety Protocol
De-energize both input and output before servicing
Verify discharge of capacitive elements (1-minute wait time)
Use CAT IV PPE during live testing
Perform dielectric tests after maintenance
Maintenance Schedule
Interval | Procedure | Acceptance Criteria |
---|---|---|
Monthly | Insulation resistance test | >500MΩ at 1kV DC |
Quarterly | Partial discharge measurement | <5pC |
Biannual | Dielectric strength verification | >4.5kV/1min |
Annual | Attenuation performance test | ±3dB of initial spec |