LQLVF 50KVA/2*142.9A Power Isolation & Noise Filter: Dual-Line EMI Protection for 0.35kV Systems

50KVA dual-line power isolation filter with >60dB EMI attenuation, 5kV insulation, and 45-65Hz frequency range for critical 0.35kV systems.


  • US$ 1,918.00
  • Lead time: 30 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQLVF 50KVA/2*142.9A Power Isolation & Noise Filter: Advanced Dual-Line Protection for Sensitive Equipment

Core Technical Specifications

ParameterSpecification
ModelLQLVF 50KVA/2*142.9A
ConfigurationSingle Phase, Dual Line
Rated Capacity50kVA
Input/Output Voltage0.35kV
Rated Current142.9A per Line
Frequency Range45-65Hz
Full-Load Operation60 minutes at 100% rating

Advanced Performance Specifications

  • Attenuation:

    • 40kHz-100kHz: >40dB

    • 100kHz-1MHz: >60dB

  • Partial Discharge: <3pC (Ultra-low noise emission)

  • Insulation Withstand: >5kV for 1 minute (input/output)

  • Insertion Loss: <0.25dB across 45-65Hz

  • Isolation Resistance: >1GΩ at 500V DC

Dual-Line Isolation Technology

  • Galvanic Isolation: 4kV basic insulation between lines

  • Independent Noise Control: Separate EMI filtering for each power line

  • Ground Loop Prevention: Eliminates common-mode interference

  • Surge Protection: 10kV/μs transient response capability

Engineering Design Features

  • Wide-Frequency Reactors: Nanocrystalline cores for 45-65Hz operation

  • Triple-Shielded Isolation: Class-I insulation system

  • Low-PD Construction: Vacuum-encapsulated windings

  • Thermal Management: B-class insulation (130°C rating)

Critical Applications

  • Medical imaging equipment power isolation

  • Semiconductor fabrication tool power

  • Precision laboratory instrumentation

  • Aerospace test equipment power

  • Pharmaceutical manufacturing systems

"Combined isolation and filtering with <3pC PD levels is essential for sensitive equipment where ground loops and EMI can compromise microvolt-level measurements."

– Journal of Medical Engineering & Technology

Installation Guidelines

  1. Mount on non-conductive surfaces using isolation bushings

  2. Maintain 100mm clearance from grounded surfaces

  3. Use 35mm² shielded twisted-pair cables

  4. Implement isolated ground for each line (<0.05Ω resistance)

  5. Verify insulation resistance before energization

Insulation Performance Validation

TestStandardResult
Dielectric StrengthIEC 60664-1>5kV/1min (input-output)
Partial DischargeIEC 60270<3pC at 1.5Ur
Impulse WithstandIEC 61000-4-56kV/3kA pass
Creepage DistanceIEC 60950>12mm (Pollution Degree 2)

Compliance & Standards

  • IEC 60601-1-2 (Medical EMC)

  • EN 55011 Class A (Industrial emissions)

  • ANSI/AAMI ES60601-1 (Medical safety)

  • IEC 61010-1 (Lab equipment safety)

Safety Protocol

  • De-energize both input and output before servicing

  • Verify discharge of capacitive elements (1-minute wait time)

  • Use CAT IV PPE during live testing

  • Perform dielectric tests after maintenance

Maintenance Schedule

IntervalProcedureAcceptance Criteria
MonthlyInsulation resistance test>500MΩ at 1kV DC
QuarterlyPartial discharge measurement<5pC
BiannualDielectric strength verification>4.5kV/1min
AnnualAttenuation performance test±3dB of initial spec