High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

SF6 Testing Instrument

LQHV-625 SF6 Gas Recovery Device - Efficient SF6 Gas Purification & Recycling System

The LQHV-625 SF6 Gas Recovery Device provides vacuum, purification, and liquid storage of sulfur hexafluoride gas for GIS equipment maintenance. Complies with DL/T 506-2018 standards with built-in filtration and heating systems.


  • US$1.00; Negotiated Price
  • Lead time: 30days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHV-625 SF6 Gas Recovery Device: Complete Gas Management Solution

Professional-grade equipment for efficient recovery and purification of sulfur hexafluoride (SF6) gas from high-voltage electrical equipment. Complies with DL/T 506-2018 industry standards.

Product Parameter

Technical Parameters

RecoveryInitial recovery pressure ≤0.8MPa
Final recovery pressure ≤50KPa
Recovery time: For 1 m3 SF6 gas volume with initial pressure of 0.8MPa, recovery to the final pressure of 50KPa, the recovery time is less than 2.5 hours
Aeration1 m3 SF6 gas volume with initial pressure of 133Pa is charged to 0.8mpa, and the charging time is less than 0.8 hours
Vacuum extractionThe limit vacuum degree of the device is less than or equal to 10 Pa, and the time required to vacuum the 1 m3 SF6 gas volume with an initial pressure of 0.1MPa to 133Pa is less than 1.0 hours
StorageStorage container volume 0.05m3
Nominal liquid storage capacity 50kg
Maximum storage pressure 3.8MPa
DecontaminationFor SF6 gas with water content below 1000PPM (volume ratio), after recovery and purification by the device, the water content is less than 60PPM (weight ratio), and the oil content is less than 10PPM (weight ratio).
Annual leakage rate≤1% nominal storage
Noise≤75dB(A) Sound pressure level
Operating ambient temperature-10℃-40 ℃
Power sourceAC three-phase five-wire system 50Hz 400V±10%
Power≤5kW
WeightAbout 545kg
Overall dimensions (L × W × H)1450×810×1200mm3

Main component performance parameters

Index nameSF6 Gas Recovery Device
Power supply AC380(three five-wire, phase sequence automatic conversion)
Rated maximum gas storage pressure (20℃)≤4MPa
Limiting vacuum≤10Pa
Device vacuum maintenanceAt 133Pa pressure for 24H, the vacuum value rose < 400Pa
SF6 CompressorFrench Meyoule
Compressor pumping rate7m3/h (customizable)
Vacuum pump2X-4
Vacuum pump pumping rate15m3/h
Recovery device ADAPTS to inlet initial pressure (20℃)0-1.0 MPa
Final pressure of electrical equipment recovery (20℃)≤50Kpa
Gas oil control after recoveryDomestic oil content < 10μg/g
Unit annual air leakage rate< 1%
Continuous trouble-free operation time of the device≥1000h
Cumulative trouble-free running time≥5000h
Noise levelMachine ≤75dB(A)
Theoretical liquid storage capacity50kg
Refrigerated liquefaction compressorDombe
Refrigerated storage tank50L
Recovered gas moisture60PPM/V
After recovery of gas oil10PPM/V
Dry filtration systemVacuum heating activation regeneration
Initial gas pressure≤133pa
Charging final pressure0.8 mpa
Inflation rate≥5m3/h
Gasification modeElectric heating automatic temperature control
Vehicle typepush-type
Overall dimension1450×810×1200cm3
Machine weightAbout 545kg
Cooling modeAir cooling
Filtration systemThe use of American HASON technology, three-stage filtration - can higher remove the recovered SF6 gas in the water, oil, particulate impurities and dust, to ensure that the recovered SF6 gas reuse

Concise parameter table

Model numberSF6 Gas Recovery Device
Vacuum pump pumping speed15m3/h
Limiting vacuum10Pa
Vacuum pumpDomestic bipolar vacuum pump
SF6 Recovery compressor7m3/h
Stress2.5 MPa
Compressor manufacturerFrench Meyoule
Filter particle0.02 micron
Oil contentHigh Efficiency (PPM)
Acid number0.1 parts per million
Hydrolyzable fluoride0.2 parts per million
Biotoxicityno
Moisture≤60PPM
SF6 purity99.9% or higher
SF6 storage tank50L
SF6 tank materialCarbon steel
Refrigeration systemHigh quality and efficient compressor
FilterAmerican original
DryerAmerican original
Vacuum gaugepointer
ValveUnique technology (built-in butterfly seal to ensure that multiple switches do not leak)

Advanced System Features

1. Intelligent Protection System

  • Phase sequence protector prevents motor reversal

  • Automatic temperature control (-20°C operation capability)

  • Overload and short-circuit protection

2. Maintenance-Free Design

  • Built-in regeneration system for desiccant reactivation

  • Self-cleaning particulate filters

  • Oil-free compression system

3. Ergonomic Mobility

  • High-grade casters with floor protection

  • Compact footprint (1200×800×1100mm)

  • Integrated control panel

Working Principle

The LQHV-625 performs gas recovery through a four-stage process:

  1. Extraction: Withdraws SF6 gas from equipment via compressor

  2. Liquefaction: Cools gas to liquid state for storage

  3. Purification: Multi-stage filtration removes:

    • Moisture (dew point ≤ -60°C)

    • Decomposition byproducts (SO2, HF)

    • Particulate contaminants

  4. Recharging: Returns purified gas to equipment

Industry Compliance

Meets critical standards for SF6 gas handling:

  • DL/T 506-2018 (SF6 Gas Recycling Device Technical Specifications)

  • IEC 60480 (Guidelines for SF6 reuse)

  • GB/T 8905 (SF6 Gas Handling Regulations)

Why Choose LQHV-625?

  • Cost Savings: Recycles up to 95% of SF6 gas (market value $20-$50/kg)

  • Environmental Safety: Prevents greenhouse gas emissions (SF6 GWP=23,900)

  • Maintenance Efficiency: 30% faster recovery than conventional units

  • Operator Protection: Fully enclosed gas path prevents exposure

Contact our technical team for customized SF6 gas management solutions for your substation or manufacturing facility.

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message