High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

800kV ~ 1600kV Range

LQHIVG 900KV-67.5KJ Impulse Voltage Generator - High-Capacity Testing Solution

Technical specifications of the 67.5kJ impulse generator with ±900kV output, adjustable charging (30-90s), and IEC-compliant waveform control for high-energy testing.


  • US$ 36,066.00
  • Lead time: 75days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHIVG 900KV-67.5KJ Impulse Voltage Generator: High-Capacity Testing Solution

Product Overview

The LQHIVG 900KV-67.5KJ Impulse Voltage Generator delivers industry-leading 67.5kJ testing energy for critical high-voltage applications in power transmission, electrical infrastructure, and industrial equipment validation. Featuring a robust 6-stage design with 1µF stage capacitance, this IEC 60060-compliant solution provides ±3% waveform accuracy and adjustable 30-90s charging for versatile testing scenarios.

Compliance with International Standards

  • IEC 60060-1/2-2010: High-voltage test definitions and measurement protocols

  • IEC 61083-1/2: Instrumentation for impulse tests

  • ANSI/IEEE 4a-2001 & 1122-2007: Testing techniques and digital recording

  • ASTM D69/D2518: Electrical insulation standards

  • GB311/GB16927: Waveform compliance certification

Technical Specifications

ParameterSpecification
Rated Voltage±900kV
Rated Energy67.5kJ
Stages6 (150kV/stage)
Stage Capacitance1µF (2×2µF capacitors at 100kV)
Stage Energy11.25kJ
Voltage Stability<±1.0%
Charging Time30-90s adjustable

Waveform Performance

Lightning Impulse Full-Wave

  • Waveform: 1.2±30%μs / 50±20%μs

  • Peak Tolerance: ±3%

  • Peak Oscillation: <5% of amplitude

  • Minimum Efficiency: ≥90% (no load)

Lightning Chopping Wave

  • Duration: 2-6μs

  • Peak Deviation: ≤3%

  • Minimum Efficiency: ≥80% (no load)

Operational Features

  • Advanced Capacitor Configuration: Dual 2µF capacitors per stage at 100kV

  • Adjustable Charging: 30-90s programmable charging time

  • Cycling Performance:

    • 120s cycle (>70% voltage)

    • 90s cycle (<70% voltage)

  • Precision Control:

    • Synchronous range: 10%-100% rated voltage

    • Polarity deviation: <20%

    • Discharge failure rate: <2%

Industrial Applications

  1. High-capacity transformer impulse testing

  2. Electrical insulation system validation per ASTM D2518

  3. Power transmission line surge protection testing

  4. Industrial switchgear certification

  5. Renewable energy infrastructure testing

Technical Advantages

  • Industry-Leading Capacity: 67.5kJ energy output for demanding test scenarios

  • Robust Capacitor Design: Dual 2µF capacitors per stage ensure stable 150kV charging

  • Operational Flexibility: 30-90s adjustable charging time accommodates diverse test requirements

  • Precision Waveform Control: ±3% voltage tolerance meets GB16927 requirements

  • Safety Assurance: <2% discharge failure rate across full voltage range

>>>WhatsApp Communication<<<