800kV ~ 1600kV Range
LQHIVG 1200KV-120KJ Impulse Voltage Generator: Industry-Leading Energy Capacity
Product Overview
The LQHIVG 1200KV-120KJ Impulse Voltage Generator sets a new standard in high-energy testing with its unprecedented 120kJ capacity and 20kJ per stage energy output. Designed for national research centers, industrial test facilities, and university laboratories, this 6-stage generator delivers precision lightning impulse and chopping wave performance compliant with IEC, IEEE, and GB standards. Specialized for power cable flashover testing and non-uniform pollution research, it enables critical infrastructure validation under real-world conditions.
Compliance with International Standards
IEC 60060-1/2-2010: High-voltage test definitions and measurement protocols
IEC 61083-1/2: Instrumentation for impulse tests
ANSI/IEEE 4a-2001 & 1122-2007: Testing techniques and digital recording
ASTM D69/D2518: Electrical insulation standards
GB311/GB16927: Waveform compliance certification
Technical Specifications
Parameter | Specification |
---|---|
Rated Voltage | ±1200kV |
Rated Energy | 120kJ |
Stages | 6 |
Stage Voltage | 200kV |
Stage Capacitance | 1.0µF |
Stage Energy | 20kJ |
Voltage Stability | <±1.0% |
Waveform Performance
Lightning Impulse Full-Wave
Waveform: 1.2±30%μs / 50±20%μs
Peak Tolerance: ±3%
Peak Oscillation: <5%
Minimum Efficiency: ≥90% (no load)
Switching Impulse Wave
Efficiency: ≥70% (with 1000pF load)
Applications: Transformer and breaker testing
Chopping Wave
Duration: 2-5μs
Compliance: Meets GB16927 requirements
Operational Features
High-Efficiency Design: 20kJ per stage energy capacity
Precision Control:
Synchronization range: 10%-100% voltage
Polarity deviation: <20%
Discharge failure rate: <2%
Advanced Cycling:
120s cycle (>70% voltage)
Continuous operation (<70% voltage)
Voltage Stability: <±1.0% charging instability
Industrial Applications
National high-voltage research facilities
University power engineering laboratories
Power cable impulse flashover testing
Insulation performance under non-uniform pollution
Transmission line equipment certification
High-capacity transformer testing
Renewable energy grid integration studies
Technical Advantages
Industry-Leading Energy Capacity: 120kJ total with 20kJ per stage
Research-Grade Efficiency: ≥90% voltage utilization for lightning tests
Specialized Pollution Testing: Non-uniform contamination analysis for power cables
Robust Capacitor Design: 1.0µF/200kV modules ensure stability
Continuous Operation Capability: Uninterrupted testing below 70% voltage
Multi-Standard Compliance: Meets IEC, IEEE, and GB requirements