Power Cable
HCTS-1667A/50kVA Cross-Core Heating Transformer
Our open-type portable heating transformer delivers precision performance for power cable heat cycle testing, designed for field and laboratory applications with 1667A continuous current capacity.
Key Specifications
Rated Capacity: 50kVA
Output Voltage: 30V (excitation winding 0.38kV)
Current Rating: 1667A per winding (131.6A excitation)
Waveform Accuracy: ≤3% deviation
Technical Performance
Parameter | Value |
---|---|
Frequency | 50Hz/60Hz |
Impedance Voltage | ≤10% |
Overload Capacity | 110% rated current for 3 minutes |
Noise Level | ≤65dB |
Dielectric Loss | <0.5% |
Dimensions | 600×420×870mm |
Color | Safety red |
System Configuration
Dual-Loop Test Architecture
High Voltage Test Loop: For dielectric/impulse testing
Temperature Monitoring Loop: With 16-channel sensor inputs
Frequently Asked Questions
What cable sizes does this support?
Himalayal offers three structural configurations:
Closed Structure: For small diameter cables
Side-Open Design: For medium cables (manual loading)
Top-Open Design: For heavy cables requiring crane assistance
What are the thermal operating limits?
Continuous operation at 100% rated current
Winding temperature rise <65K
Oil temperature rise <55K
Safety & Compliance
All transformers include:
Overcurrent protection circuits
Thermal overload safeguards
Isolated control windings
IP-rated terminal covers (optional)
Consult our engineering team for custom configurations based on your cable specifications (conductor material, insulation type, and test requirements).