Power Cable
HCTS-1500A/10V/15kVA Heating Transformer
Compact yet powerful solution for power cable heat cycle testing, delivering 1500A continuous current with precision 10V output for accurate thermal simulations.
Key Specifications
Rated Capacity: 15kVA (single unit)
Input Voltage: 380V ±10%
Output: 10V/1500A
Core Design: 280mm cross-hole diameter
Technical Performance
Parameter | Specification |
---|---|
Waveform Deviation | <3% |
Impedance Voltage | ≤10% |
Overload Capacity | 110% current for 3 minutes |
Noise Level | ≤65dB |
Dielectric Loss | <0.5% |
Cooling System | Automatic dry cooling |
Color Options | Red/Black/Yellow (optional) |
Design Features
Core Technology
Optimized 280mm cross-hole design
Precision wound copper windings
Low-reactance configuration
Thermal Management
Fan-assisted dry cooling
Continuous operation at rated current
Automatic thermal protection
Test Applications
Type testing per IEC 60840/62067
Medium voltage cable qualification
Cable accessory thermal cycling
Factory acceptance testing
Safety & Reliability
Overcurrent auto-disconnect
Winding temperature monitoring
Short-circuit protected design
Insulation resistance alarms
Configuration Notes
Standard 3m test leads included
Optional current monitoring package
Mobile test cart available
Available in standard configuration or customized for specific cable testing requirements - contact our engineers for technical consultation.