High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

Standard D&L Calibrating

LQSS-11 Dielectric Loss Calibrator | 11-Range HV Bridge Validation System (1×10⁻⁵ Precision)

The LQSS-11 Calibrator offers 11 precision grades (1×10⁻⁴ to 1×10⁻⁵) with a 10kV/100pF SF6 capacitor for field/lab validation of tan delta bridges per IEC 61869.


  • US$ 2,952.00
  • Lead time: 30 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQSS-11 Dielectric Loss Calibrator | 11-Range HV Bridge Validation System

The LQSS-11 Standard Dielectric Loss Calibrating Device revolutionizes high-voltage test equipment validation with 11 selectable precision grades and an integrated 10kV/100pF SF6 reference capacitor (1×10⁻⁵ tan δ). Designed for field technicians and calibration labs.

Key Advantages

  • 11-Point Calibration: 1×10⁻⁴ to 1×10⁻⁵ full-range verification

  • SF6 Reference Standard: 10kV/100pF gas-insulated capacitor (Grade 11)

  • Troubleshooting Mode: Isolate measurement errors in HV bridges

  • Portable Design: 25% lighter than previous models (field-deployable)

Technical Specifications

ParameterSpecification
Calibration Range1×10⁻⁴ to 1×10⁻⁵ (11 grades)
Reference Capacitor10kV/100pF SF6 (customizable to 50kV)
Temperature Stability±0.3%/°C (-20°C to +50°C)
InterfacesLEMO/SHV connectors (HV compatible)

Calibration Grades

Grade 1    1×10⁻⁴ (Ultra-Precision)

Grades 2-3    3×10⁻⁴ to 5×10⁻⁴

Grades 4-6    1×10⁻³ to 5×10⁻³

Grades 7-9    1×10⁻² to 5×10⁻²

Grade 10    0 (Null Reference)

Grade 11    SF6 Capacitor @ 1×10⁻⁵

Critical Applications

Utility Maintenance

Validate Doble/Megger test sets for 500kV transformers

Cable OEMs

Quality control for HV cable tan δ testing

Research Labs

Dielectric studies with NIST-traceable standards

Step-by-Step Calibration

  1. Connect to tan delta bridge (HCL 2876/2840 compatible)

  2. Select grade matching DUT's expected loss factor

  3. Compare readings against reference values

  4. Diagnose deviations >±2% as bridge calibration issues

Compliance & Standards

  • IEC 61869-11 (High-voltage measurement standards)

  • IEEE 4-2013 (HV testing procedures)

  • ISO 17025 (Lab accreditation requirements)

Why Upgrade to LQSS-11?

  • More Grades: 11 steps vs. competitors' 5-8

  • Higher Capacity: 100pF reference (vs. typical 50pF)

  • Customizable: SF6 capacitor voltage/values on request

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message