High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

Automatic Control & Measuring System

LQHCS 2000A Automatic Control System for High Voltage Impulse Testing | Technical Specifications

Technical specifications and features of the LQHCS 2000A automatic control system for high voltage impulse generators, including control parameters, measurement capabilities and safety features.


  • US$ 13,115.00
  • Lead time: 30 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHCS 2000A Automatic Control System for High Voltage Impulse Testing

The LQHCS 2000A represents a state-of-the-art automatic control system designed for precision management of high voltage impulse generators. This advanced system combines robust PLC technology with intuitive user interfaces to deliver reliable performance in demanding high voltage testing environments.

Technical Parameters and Specifications

ParameterSpecification
Charging Voltage
  • Setting range: 0-100.0kV

  • Operating range: 10.0-100.0kV

  • Setting deviation: <±1%

  • Instability: ±1%

  • Resolution: 0.1kV

Charging Time
  • Setting range: 20-190s

  • Resolution: 1s

  • Alarm time-delay: 2s

Voltage Ramp SettingsSetting range: 1-999 steps
Protection Features
  • Adjustable over-current protection

  • Adjustable over-voltage protection

  • Selectable trends charging protection

  • Configurable static charging protection

Trigger Pulse
  • Voltage: >15kV

  • Rising time: <100ns

  • Switchable polarity

Output Stability>99%
Physical Dimensions750×900×1250mm (W×H×D)

Advanced Control Features

The HCS2000A controller supports three operational modes:

  • Manual control: For precise operator-directed testing

  • Automatic control: For predefined test sequences

  • Programmed control: For complex automated test routines

Measurement and Display Capabilities

Real-time Measurements

  • DC charging voltage

  • Transformer primary current

  • Generator sphere gap distance

System Status Indicators

  • Main power connector state

  • Ground device status

  • Sphere gap trigger state

  • Charging voltage polarity

Core Control Functions

  1. Independent manual/automatic/programmed operation modes

  2. Controllable silicon regulation with voltage feedback

  3. Adjustable spark gap distance (manual/auto) with visual display

  4. Configurable time-delay chopping gap trigger with feedback

  5. Constant current charging with 0.5% voltage stability

  6. LCD display showing charging parameters (1% accuracy)

  7. Direct parameter input via touch panel interface

  8. Comprehensive charging anomaly protection system

  9. Detailed system status indicators including:

    • Spontaneous combustion

    • Trigger failure

    • Charging abnormalities

    • System stability

  10. Integrated grounding control for all system components

  11. One-button polarity reversal

  12. Flexible charging process control options

  13. Configurable audible alarm system

Safety and Protection Systems

The LQHCS 2000A incorporates multiple layers of protection:

Primary Protection Mechanisms

  • Adjustable over-current protection

  • Configurable over-voltage protection

  • Abnormal discharge protection

Safety Interlocks

  • Door open/close interlock

  • Ground facility interlock

  • Polarity reversal interlock

Operation Monitoring

  • Visual indicators for all system states

  • Error condition displays

  • Misoperation warnings

Precision Measurement System

Amplitude Measurement

  • Optional impulse peak voltmeter

  • Input range: 100V-1000V (impulse voltage)

  • Measurement uncertainty: <1%

Waveform Analysis

  • TDS3012 digital oscilloscope (standard)

  • Dual channel, 100MS/s, 9-bit resolution

  • Higher resolution options available

  • Windows 7/8/10 compatible software

  • 19" LCD monitor with full peripherals

Data Processing

Industrial-grade control computer for advanced waveform analysis. Custom configurations available with alternative measurement devices upon request.

Standards Compliance

The LQHCS 2000A system meets the following international standards:

  • IEC 60060-1-2010: High-voltage test techniques - General definitions and test requirements

  • IEC 60060-2-2010: High-voltage test techniques - Measuring systems

  • IEC 61083-1-2001: Instruments for measurements in high-voltage impulse tests

  • IEC 61083-2-1996: Digital recorders for high-voltage tests - Software evaluation

  • ANSI/IEEE 4a-2001: Techniques of High-Voltage Testing

  • ANSI/IEEE 376-1975: Measurement of Impulse Strength and Impulse Bandwidth

  • ANSI/IEEE 1122-2007: Digital Recorders for High-Voltage Impulse Tests

Typical Applications

The LQHCS 2000A system is ideally suited for:

  • High voltage component testing laboratories

  • Insulation material research facilities

  • Electrical equipment manufacturing QA

  • Power transformer impulse testing

  • Cable and surge arrester evaluation

  • University high voltage research programs

System Overview

The LQHCS 2000A Automatic Control System delivers precision control for high voltage impulse testing applications. With its comprehensive safety features, flexible operating modes, and compliance with international standards, this system provides reliable performance for both industrial and research applications. The combination of robust hardware and intuitive software interface makes the LQHCS 2000A an excellent choice for demanding high voltage testing environments requiring repeatable, accurate results.

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message