>600kVA Range
LQHCR 750KVA-3KV Multi-Frequency Reactor: 50-120Hz Operation & Ultra-Low PD Design
Product Overview
The LQHCR 750KVA-3KV is a specialized oil-immersed compensation reactor engineered for multi-frequency operation (50-120Hz) with ultra-low partial discharge characteristics. Featuring configurable taps for high-frequency testing, it delivers precise reactive power control in demanding industrial applications.
Technical Specifications
Parameter | Specification |
---|---|
Model | LQHCR 750KVA-3KV |
Frequency Range | 50/60/100/120Hz |
Rated Capacity | 750KVA |
Rated Voltage | 3kV (with test taps for 100/120Hz) |
Rated Current Options | 50A, 100A, 150A, 200A, 250A |
Linearity | < +1% |
Sound Level | < 70dB |
Temperature Rise Limits | Winding ≤65K, Oil surface ≤55K |
Partial Discharge (PD) | <5pC @100% Vn, <3pC @80% Vn |
Advanced Performance Features
Multi-Frequency Operation
Specialized winding design with configurable taps enables stable performance across 50-120Hz power systems.
Ultra-Low Partial Discharge
Class-leading PD levels ensure long-term insulation integrity:
<5pC at 100% rated voltage
<3pC at 80% rated voltage
Enhanced Insulation System
Full insulation design withstands 10kV/min terminal-to-ground tests with zero discharge anomalies.
Thermal Management
Optimized oil circulation paths
Temperature-stabilated dielectric fluid
Winding hot-spot monitoring capability
Protection & Safety Systems
Over-Current Capability
Operates at 120% rated current for 10 minutes without winding damage or distortion.
Over-Voltage Capability
Withstands 110% rated voltage for 10 minutes without insulation degradation.
Continuous Operation
60 minutes at 100% rated voltage/current while maintaining temperature limits.
Frequency-Specific Applications
Frequency | Primary Application | Specialized Use Case |
---|---|---|
50Hz | European power grids | Industrial motor compensation |
60Hz | North American systems | Data center UPS systems |
100Hz | Aerospace ground support | Avionics testing |
120Hz | Specialized manufacturing | High-speed motor drives |
Industrial Implementation
Power Quality Labs
Multi-frequency harmonic analysis and compliance testing
Semiconductor Fabs
Precision power conditioning for sensitive equipment
Military Systems
Naval vessel power systems requiring 100/120Hz operation
Renewable Research
Grid simulation for next-generation energy systems
Installation Requirements
Maintain minimum 1.2m clearance for high-frequency operation
Grounding resistance ≤3Ω (IEEE 80)
Ambient temperature ≤40°C with derating above
Install on vibration-isolated foundation (ISO 10816-8)
Testing & Maintenance Protocol
Test | Frequency | Standard |
---|---|---|
Partial discharge measurement | Annually | IEC 60270 |
Frequency response analysis | After installation | IEEE C57.149 |
Insulation resistance | Quarterly | IEC 62631 |
Winding resistance | Biannually | IEC 60076 |
Compliance Standards
IEC 60076: Power transformers
IEEE C57.12.90: Test code for reactors
EN 50588: Industrial reactor standards
MIL-STD-704F: Aircraft electrical power
GB/T 16927: High-voltage testing