LQHCR 750KVA-3KV Multi-Frequency Reactor: 50-120Hz Operation & Ultra-Low PD Design

Technical specifications for LQHCR 750KVA-3KV multi-frequency compensation reactor with 50-120Hz operation and ultra-low partial discharge (<5pC). Includes thermal design and safety features.


  • US$ 12,787.00
  • Lead time: 60 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHCR 750KVA-3KV Multi-Frequency Reactor: 50-120Hz Operation & Ultra-Low PD Design

Product Overview

The LQHCR 750KVA-3KV is a specialized oil-immersed compensation reactor engineered for multi-frequency operation (50-120Hz) with ultra-low partial discharge characteristics. Featuring configurable taps for high-frequency testing, it delivers precise reactive power control in demanding industrial applications.

Technical Specifications

ParameterSpecification
ModelLQHCR 750KVA-3KV
Frequency Range50/60/100/120Hz
Rated Capacity750KVA
Rated Voltage3kV (with test taps for 100/120Hz)
Rated Current Options50A, 100A, 150A, 200A, 250A
Linearity< +1%
Sound Level< 70dB
Temperature Rise LimitsWinding ≤65K, Oil surface ≤55K
Partial Discharge (PD)<5pC @100% Vn, <3pC @80% Vn

Advanced Performance Features

Multi-Frequency Operation

Specialized winding design with configurable taps enables stable performance across 50-120Hz power systems.

Ultra-Low Partial Discharge

Class-leading PD levels ensure long-term insulation integrity:

  • <5pC at 100% rated voltage

  • <3pC at 80% rated voltage

Enhanced Insulation System

Full insulation design withstands 10kV/min terminal-to-ground tests with zero discharge anomalies.

Thermal Management

  • Optimized oil circulation paths

  • Temperature-stabilated dielectric fluid

  • Winding hot-spot monitoring capability

Protection & Safety Systems

Over-Current Capability

Operates at 120% rated current for 10 minutes without winding damage or distortion.

Over-Voltage Capability

Withstands 110% rated voltage for 10 minutes without insulation degradation.

Continuous Operation

60 minutes at 100% rated voltage/current while maintaining temperature limits.

Frequency-Specific Applications

FrequencyPrimary ApplicationSpecialized Use Case
50HzEuropean power gridsIndustrial motor compensation
60HzNorth American systemsData center UPS systems
100HzAerospace ground supportAvionics testing
120HzSpecialized manufacturingHigh-speed motor drives

Industrial Implementation

Power Quality Labs

Multi-frequency harmonic analysis and compliance testing

Semiconductor Fabs

Precision power conditioning for sensitive equipment

Military Systems

Naval vessel power systems requiring 100/120Hz operation

Renewable Research

Grid simulation for next-generation energy systems

Installation Requirements

  1. Maintain minimum 1.2m clearance for high-frequency operation

  2. Grounding resistance ≤3Ω (IEEE 80)

  3. Ambient temperature ≤40°C with derating above

  4. Install on vibration-isolated foundation (ISO 10816-8)

Testing & Maintenance Protocol

TestFrequencyStandard
Partial discharge measurementAnnuallyIEC 60270
Frequency response analysisAfter installationIEEE C57.149
Insulation resistanceQuarterlyIEC 62631
Winding resistanceBiannuallyIEC 60076

Compliance Standards

  • IEC 60076: Power transformers

  • IEEE C57.12.90: Test code for reactors

  • EN 50588: Industrial reactor standards

  • MIL-STD-704F: Aircraft electrical power

  • GB/T 16927: High-voltage testing