High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

Water Conditioning Unit

LQCTS-120kW Water Conditioning Unit: Technical Specifications & Industrial Applications

Explore technical specs of LQCTS-120kW water conditioning unit for HV testing. Features 500L capacity, 4atm pressure rating, and >2MΩ-cm resistivity for stable thermal management.


  • US$ 19,672.00
  • Lead time: 45 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQCTS-120kW Water Conditioning Unit: Critical Thermal Management for High-Voltage Systems

Core Functionality

The LQCTS-120kW water conditioning unit removes heat generated by electrical currents in high-voltage terminals while deionizing circulating water. Maintaining >2MΩ-cm resistivity ensures safe, efficient operation of sensitive HV equipment.

Technical Specifications

ParameterValue
Power Supply220V/20A, 50/60Hz
Max Cooling Capacity120 kW
Water Capacity500 Liters
Max Operating Temperature60°C
Max Pressure Rating4 atm
Conductivity Range0.1-2 μS/cm
Ambient Temp Range3°C to 35°C
Water Pipe Connections1×2" Inlet / ¾" Head
Dimensions (L×W×H)1200×1400×1700 mm
Dry Weight272 kg

Critical Operational Features

  • Advanced Deionization Maintains >2MΩ-cm water resistivity to prevent electrical conductivity

  • Thermal Protection Auto-shutdown when cooling water exceeds 20°C or flow drops below 45L/min

  • Multi-Layer Safeguards Pump reversal protection + low-water cutoff system

  • External Cooling Integration Required when water temperature exceeds 40°C

Industrial Applications

High-Voltage Testing Systems

Dissipates heat from transformer terminals, bushings, and switchgear during extended load tests.

Power Electronics Cooling

Manages thermal loads in IGBT stacks and rectifier assemblies for HVDC converters.

Research Laboratories

Provides stable thermal conditions for partial discharge measurement equipment.

Operational Protocols

  • Verify water level before startup (unit disables if low)

  • Monitor flow velocity ≥45L/min to prevent overheating

  • Initiate external cooling when ambient temperatures >35°C

  • Monthly conductivity checks to ensure >2MΩ-cm resistivity

Troubleshooting Guide

SymptomDiagnostic Action
Unit fails to start1. Check water level
2. Verify pump rotation direction
Reduced cooling efficiency1. Measure flow velocity
2. Inspect external cooling systems
Conductivity alarms1. Test deionization cartridges
2. Check for contaminant ingress

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message