High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

≤100kVA Range

HET 66kVA Triple-Tap Exciter Transformer (2.2kV-6.6kV) | <5% Impedance Voltage

Precision 66kVA exciter transformer with three voltage taps (2.2kV/3.85kV/6.6kV), <5% impedance voltage, and advanced electrostatic shielding for flexible high-voltage testing.


  • US$ 8,526.00
  • Lead time: 45 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

HET 66kVA Triple-Tap Exciter Transformer (2.2kV-6.6kV)

Engineered for versatile testing applications, the HET 66kVA exciter transformer offers three configurable output taps (2.2kV/3.85kV/6.6kV) with <5% impedance voltage. Features ONAN cooling and comprehensive safety systems for laboratory and industrial use.

Technical Specifications

ParameterTap I (6.6kV)Tap II (3.85kV)Tap III (2.2kV)
Output Voltage6.6kV3.85kV2.2kV
Output Current10A17A30A
Common Parameters
Input Voltage415V
Rated Capacity66kVA
Frequency50Hz
Impedance Voltage<5%

Core Design Features

Advanced Insulation System

  • Electrostatic Shielding: Dedicated HV-LV winding isolation layer

  • Cylinder-Type Windings: Balanced top/bottom area distribution

  • Compound Insulation Tube: Reduces partial discharge (PD) and shields iron core

  • Voltage Stabilization: Electrostatic compensation technology

Mechanical Construction

  • ONAN Cooling: Oil Natural Air Natural system

  • Steel Housing: Shell-type oil tank with conservator

  • Mobile Design: Wheel-mounted with movable base

  • Corona-Free Bushings: Fiberglass HV bushings (6.6kV rated)

Protection Systems

Electrical Protection

  • Zinc oxide arresters on all HV outputs

  • Piezoresistors per HV terminal

  • Isovolumetric capacitance core for bushings

Structural Safety

  • Porcelain LV bushings

  • Multi-layer turn-to-turn insulation

  • Flashover protection for all insulation layers

Performance Advantages

  1. Three-Tap Flexibility: Single-unit solution for multiple test voltages

  2. High Current Capacity: Up to 30A output at 2.2kV

  3. Low Impedance: <5% voltage drop ensures accuracy

  4. Field-Ready: Wheeled base for lab/field deployment

Typical Applications

  • Industrial motor testing

  • Medium-voltage cable evaluation

  • Power electronics component testing

  • Research facility voltage generation

Manufactured in compliance with IEC 60076-3 insulation standards and IEEE C57.12.00 safety requirements. Recommended maintenance interval: 2 years or 2000 operational hours.

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message