High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

≤100kVA Range

HET 60kVA Triple-Range Exciter Transformer (5kV-15kV) | <10pC Partial Discharge

Industrial-grade 60kVA exciter transformer with triple output (5kV/10kV/15kV), <10pC partial discharge, and zinc oxide arrester protection for precision high-voltage testing.


  • US$ 7,807.00
  • Lead time: 45 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

HET 60kVA Triple-Range Exciter Transformer (5kV-15kV)

Engineered for versatile high-voltage applications, the HET 60kVA exciter transformer delivers three precision outputs (5kV/10kV/15kV) with <10pC partial discharge at rated voltage. Features ONAN cooling and advanced electrostatic shielding for laboratory and industrial testing.

Technical Specifications

ParameterSpecification
Rated Capacity60kVA
Input Voltage (LV)0.4kV
Output Voltage (HV)5kV / 10kV / 15kV
Current Ratings150A (LV) / 4A (HV)
Frequency50Hz
Impedance Voltage<5%
Partial Discharge<10pC at rated voltage

Core Design Features

Advanced Insulation System

  • Electrostatic Shielding: Dedicated layer between HV windings

  • Cylinder-Type Windings: Balanced top/bottom area distribution

  • Compound Insulation Tube: Reduces partial discharge and shields iron core

  • Voltage Stabilization: Electrostatic compensation for uniform distribution

Mechanical Construction

  • ONAN Cooling: Oil Natural Air Natural system

  • Steel Housing: Shell-type oil tank with conservator

  • Mobile Design: Wheel-mounted with movable base

  • Corona-Free Bushings: Fiberglass HV bushings (15kV rated)

Protection Systems

Electrical Protection

  • Zinc oxide arresters on all HV outputs

  • Piezoresistors per HV terminal

  • Isovolumetric capacitance core for bushings

Structural Safety

  • Porcelain LV bushings

  • Multi-layer turn-to-turn insulation

  • Flashover protection for main/minor insulation

Performance Advantages

  1. Triple Voltage Output: Single-unit solution for multiple test scenarios

  2. Low Impedance: <5% voltage drop ensures accuracy

  3. Corona-Free Operation: Verified at 15kV

  4. Field Deployment: Wheeled design for test site mobility

Typical Applications

  • Power transformer testing

  • High-voltage cable evaluation

  • Industrial equipment dielectric tests

  • Research lab voltage generation

Complies with IEC 60076-3 insulation standards and IEEE C57.12.00 safety requirements. Recommended maintenance interval: 2 years or 2000 operational hours.

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message