High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

≤100kVA Range

HET 50kVA Dual-Voltage Exciter Transformer (5kV/2.5kV) – Technical Specifications & Applications

High-capacity 50kVA exciter transformer with 5kV/2.5kV dual outputs and <5% impedance. Features electrostatic shielding and zinc oxide surge protection for industrial high-voltage testing.


  • US$ 6,230.00
  • Lead time: 45 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

HET 50kVA Dual-Voltage Exciter Transformer (5kV/2.5kV) – Technical Specifications & Applications

Product Overview

The HET 50kVA exciter transformer delivers precision testing with dual-voltage outputs (5kV/2.5kV) and ultra-low impedance (<5%). Designed with ONAN cooling and advanced electrostatic shielding, it complies with IEC 60076-11 standards for demanding industrial applications.

Electrical Specifications

ParameterSpecification
Rated Capacity50kVA
Output Configurations:
• High Range5kV @ 10A
• Standard Range2.5kV @ 20A
Frequency50Hz ±1%
Impedance Voltage<5%

Key Features

Dual-Voltage Operation

  • Independent winding taps for each voltage range

  • Precision voltage ratio (±0.5% accuracy)

  • No-load tap changer for safe switching

Thermal Performance

  • ONAN cooling with 25# transformer oil

  • Continuous operation at full rated capacity

  • Winding temperature rise ≤65K

Protection Systems

1. Overvoltage Protection

  • Piezoresistors on all HV outputs

  • Zinc oxide arresters (15kA rating per IEC 60099-4)

  • Dual grounding points with 10mm² copper straps

2. Insulation Control

  • 5kV corona-free fiberglass bushings

  • Electrostatic shielding between HV/LV windings

  • Isovolumetric capacitance cores for stable voltage distribution

Mechanical Design

Enclosure Features

  • 12-gauge steel housing with corrosion-resistant coating

  • Wheel-mounted (4× industrial casters with brakes)

  • Shell-type oil tank with 55L conservator

Terminal Configuration

  • LV terminals: Porcelain bushings

  • HV terminals: Fiberglass-reinforced epoxy bushings

  • All bushings feature dual corona rings

Winding Technology

  • Cylinder-type windings with balanced capacitance

  • Electrostatic compensation shields

  • Inter-turn insulation (1.5mm Nomex® layers)

  • Compound insulation tubes for partial discharge control

Installation & Maintenance

Commissioning Requirements

  • Minimum 1m clearance from grounded surfaces

  • Initial oil BDV ≥45kV (2.5mm gap)

  • Pre-operation IR ≥8,000MΩ

Service Schedule

  • Monthly: Bushing contamination inspection

  • Quarterly: Oil dielectric strength testing

  • Annual: Complete winding resistance test

Typical Applications

  • Power cable withstand testing

  • Circuit breaker contact resistance tests

  • Rotating machine insulation diagnostics

  • Transformer factory acceptance tests

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message