HET 41.5kVA Triple-Range Exciter Transformer (24kV/12kV/6kV) – Technical Specifications

High-capacity 41.5kVA exciter transformer with 24kV/12kV/6kV selectable outputs, <5pC partial discharge, and electrostatic shielding. Ideal for high-voltage testing up to 24kV.


  • US$ 5,487.00
  • Lead time: 30 day

>>>WhatsApp Communication<<<

Product Details

Product Tags

HET 41.5kVA Triple-Range Exciter Transformer (24kV/12kV/6kV) – Technical Specifications

Product Overview

The HET 41.5kVA exciter transformer provides three voltage ranges (24kV/12kV/6kV) in a single unit, featuring ultra-low partial discharge (<5pC) and <5% impedance. With ONAN cooling and advanced electrostatic shielding, it meets IEC 60076-11 standards for precision high-voltage testing.

Electrical Specifications

ParameterSpecification
Rated Capacity41.5kVA
Input Voltage0.415kV
Input Current100A
Output Configurations:
• Ultra-HV Range24kV @ 1.73A
• High Range12kV @ 3.46A
• Standard Range6kV @ 6.92A
Frequency50Hz ±1%
Impedance Voltage<5%
Partial Discharge<5pC at rated voltage

Advanced Design Features

Triple-Voltage Operation

  • Independent winding taps for each voltage range

  • Precision voltage ratio (±0.5% accuracy)

  • No-load tap changer for safe switching

Dielectric Performance

  • 24kV corona-free bushings with triple corona rings

  • Electrostatic shielding between all windings

  • Isovolumetric capacitance cores for stable voltage distribution

Protection Systems

1. Overvoltage Protection

  • Piezoresistors on all HV outputs

  • Zinc oxide arresters (20kA rating per IEC 60099-4)

  • Dual grounding points with 10mm² copper straps

2. Insulation Monitoring

  • Inter-turn insulation (2mm Nomex® layers)

  • Winding temperature sensors with alarm contacts

  • Oil level indicator with minimum mark

Mechanical Construction

Enclosure Features

  • 12-gauge steel tank with ANSI 61 gray finish

  • Heavy-duty wheel base (4× 250mm casters with brakes)

  • Shell-type oil tank with 60L conservator

Terminal Configuration

  • LV terminals: Porcelain bushings (creepage ≥25mm/kV)

  • HV terminals: Fiberglass-reinforced epoxy bushings

  • All bushings have grading rings for field control

Installation & Maintenance

Commissioning Requirements

  • Minimum 1.5m clearance from grounded surfaces

  • Initial oil BDV ≥50kV (2.5mm gap)

  • Pre-operation IR ≥10,000MΩ (2.5kV megger)

Service Schedule

  • Monthly: Inspect bushing contamination

  • Quarterly: Oil DGA and moisture analysis

  • Annual: Complete winding resistance test

Typical Applications

  • Extra-high voltage cable testing

  • GIS (Gas Insulated Switchgear) commissioning

  • Power transformer routine tests

  • Research labs requiring multi-voltage testing