HET 40kVA Multi-Tap Exciter Transformer (4kV/2.5kV/1.5kV) – Complete Technical Guide

Versatile 40kVA exciter transformer with 4kV/2.5kV/1.5kV selectable outputs via manual tap-changer. Features <6% impedance and zinc oxide surge protection for flexible high-voltage testing.


  • US$ 5,113.00
  • Lead time: 30 day

>>>WhatsApp Communication<<<

Product Details

Product Tags

HET 40kVA Multi-Tap Exciter Transformer (4kV/2.5kV/1.5kV) – Complete Technical Guide

Product Overview

The HET 40kVA exciter transformer offers three voltage outputs (4kV/2.5kV/1.5kV) through a manual tap-changer, with ONAN cooling and 25# transformer oil insulation. Designed for flexible testing applications with <6% impedance voltage.

Electrical Specifications

ParameterSpecification
Rated Capacity40kVA
Input Voltage0.38kV
Input Current105.3A
Output Configurations:
• Tap I (High Range)4kV @ 10A
• Tap II (Mid Range)2.5kV @ 16A
• Tap III (Standard)1.5kV @ 26.7A
Frequency50Hz ±1%
Impedance Voltage<6%
Insulation Level1.1× rated voltage for 1min

Key Features

Manual Tap-Changer System

  • Three-position rotary switch for voltage selection

  • Mechanical interlock prevents live switching

  • Visual position indicator for tap confirmation

Thermal Performance

  • ONAN cooling with 25# transformer oil

  • Continuous operation at full rated capacity

  • Winding temperature rise ≤65K

Protection Systems

1. Overvoltage Protection

  • Piezoresistors on all HV outputs

  • Zinc oxide arresters (15kA rating) per IEC 60099-4

  • Dual ground reference points

2. Insulation Control

  • Electrostatic shielding between all windings

  • 4kV corona-free fiberglass bushings

  • Isovolumetric capacitance cores in HV bushings

Mechanical Design

Enclosure Features

  • 14-gauge steel housing with corrosion-resistant coating

  • Integrated wheel base (4× 200mm industrial casters)

  • Shell-type oil tank with 45L conservator

Terminal Configuration

  • LV terminals: Porcelain bushings (0.38kV input)

  • HV terminals: Fiberglass-reinforced epoxy bushings

  • All bushings feature dual corona rings

Winding Technology

  • Cylinder-type windings with balanced capacitance

  • Electrostatic compensation shields

  • Inter-turn insulation (1.2mm Nomex® layers)

  • Compound insulation tubes for partial discharge control

Installation & Maintenance

Commissioning Requirements

  • Minimum 1m clearance from grounded surfaces

  • Initial oil BDV ≥40kV (2.5mm gap)

  • Verify tap-changer position before energization

Service Schedule

  • Monthly: Inspect tap-changer contacts

  • Quarterly: Oil dielectric testing

  • Annual: Complete winding resistance test

Typical Applications

  • Multi-voltage cable testing systems

  • Circuit breaker contact resistance testing

  • Rotating machine insulation diagnostics

  • Transformer factory acceptance tests