High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

≤100kVA Range

HET 30kVA Dual-Frequency Exciter Transformer (2kV/1kV) – Technical Specifications

High-efficiency 30kVA exciter transformer with 2kV/1kV outputs and dual-frequency operation (50Hz/150Hz). Features <3% impedance and electrostatic shielding for precision testing applications.


  • US$ 4,971.00
  • Lead time: 30 day

>>>WhatsApp Communication<<<

Product Details

Product Tags

HET 30kVA Dual-Frequency Exciter Transformer (2kV/1kV) – Technical Specifications

Product Overview

The HET 30kVA exciter transformer delivers flexible testing capabilities with dual-frequency operation (50Hz/150Hz) and 2kV/1kV voltage outputs. Engineered with ultra-low impedance (<3%) and advanced electrostatic shielding, it complies with IEC 60076-11 for high-precision test applications.

Electrical Specifications

ParameterSpecification
Rated Capacity30kVA
Input Voltage1kV
Input Current75A
Output Voltage2kV
Output Current15A
Frequency Range50Hz / 150Hz
Impedance Voltage<3%

Key Features

Dual-Frequency Operation

  • Optimized for both power frequency (50Hz) and intermediate frequency (150Hz) testing

  • Special winding design to minimize losses at higher frequencies

Thermal Performance

  • ONAN cooling with 25# transformer oil

  • Continuous operation at 100% rated capacity

  • Winding temperature rise ≤65K

Protection Systems

1. Overvoltage Protection

  • Piezoresistors on all HV outputs

  • Zinc oxide arresters (IEC 60099-4 compliant)

  • Ground-connected via 10kA surge arresters

2. Insulation Control

  • Electrostatic shield layer between HV/LV windings

  • 2kV corona-free fiberglass bushings

  • Isovolumetric capacitance cores for stable voltage distribution

Mechanical Design

Enclosure Features

  • Steel housing with corrosion-resistant coating

  • Wheel-mounted (4× industrial casters)

  • Shell-type oil tank with 40L conservator

Terminal Configuration

  • LV terminals: Porcelain bushings

  • HV terminals: Fiberglass-reinforced epoxy bushings

  • Corona rings on all HV bushings

Winding Technology

  • Cylinder-type winding with balanced capacitance

  • Electrostatic compensation shields

  • Inter-turn insulation (1mm Nomex® layers)

  • Compound insulation tube skeleton

Installation & Maintenance

Commissioning Requirements

  • Minimum 1m clearance from grounded surfaces

  • Oil dielectric strength ≥45kV before energization

  • Initial insulation resistance ≥8,000MΩ

Service Schedule

  • Monthly: Bushing inspection

  • Quarterly: Oil testing (BDV, moisture)

  • Annual: Winding resistance measurement

Typical Applications

  • Power cable withstand testing at multiple frequencies

  • Rotating machine insulation diagnostics

  • Transformer impulse testing systems

  • High-voltage component R&D testing