≤100kVA Range
HET 30kVA/20kV Multi-Winding Exciter Transformer – Technical Specifications & Applications
Product Overview
The HET 30kVA/20kV exciter transformer features a unique 4-winding design with individual bushings for each 10kV winding. Engineered for 30-300Hz variable frequency operation, it delivers ultra-low partial discharge (<2pC) and complies with IEC 60076-11 for high-voltage testing applications.
Electrical Specifications
Parameter | Specification |
---|---|
Rated Capacity (Total) | 30kVA |
Input Voltage | 350V |
Input Current | 85.7A |
High Voltage Output: | |
• Configuration | 4 windings (2×10kV pairs) |
• Current per Winding | 1.5A |
Frequency Range | 30-300Hz |
Impedance Voltage | 10% ±5% (winding-winding) |
Partial Discharge | <2pC at rated voltage |
Advanced Design Features
Multi-Winding Configuration
Four independent 10kV windings with separate bushings
Parallel/series connection options for 10kV or 20kV operation
Individual isovolumetric capacitance cores per winding
Thermal Performance
Continuous operation: 30 minutes at full load
Winding temperature rise: ≤65K
Oil temperature rise: ≤55K (top layer)
Cooling method: ONAN with 25# transformer oil
Protection Systems
1. Overvoltage Protection
Piezoresistors on all 4 HV outputs
Zinc oxide arresters (20kA rating, IEC 60099-4)
Dual-point ground connection system
2. Insulation Control
Electrostatic shields between all HV/LV windings
20kV corona-free fiberglass bushings
Inter-turn insulation (1.5mm Nomex® layers)
Mechanical Construction
Enclosure Features
12-gauge steel tank with ANSI 61 gray finish
Quad-wheel base with locking casters (250mm diameter)
Shell-type oil tank with 50L conservator
Terminal Configuration
4× HV bushings with dual corona rings each
LV terminals: Porcelain bushings (350V input)
All connections voltage-graded per IEC 60137
Winding Technology
Cylinder-type windings with balanced capacitance distribution
Electrostatic compensation for uniform voltage gradient
Compound insulation tubes for partial discharge control
Precision top-bottom area matching (±3%)
Installation & Maintenance
Commissioning Requirements
Minimum 1.2m clearance between phases
Initial oil BDV ≥50kV (2.5mm gap)
Pre-energization IR ≥10,000MΩ
Service Schedule
Monthly: Bushing contamination checks
Quarterly: Oil dielectric testing
Annual: Winding resistance measurements
Typical Applications
Multi-terminal cable testing systems
GIS (Gas Insulated Switchgear) commissioning
Rotating machine insulation diagnostics
Partial discharge research setups