High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

≤100kVA Range

HET 25kVA Dual-Range Exciter Transformer (8kV/4kV) – Technical Specifications & Safety Guide

Industrial 25kVA exciter transformer with 8kV/4kV dual outputs, <4% impedance voltage, and electrostatic shielding. Features zinc oxide surge protection and corona-free bushings for safe HV testing.


  • US$ 4,589.00
  • Lead time: 30 day

>>>WhatsApp Communication<<<

Product Details

Product Tags

HET 25kVA Dual-Range Exciter Transformer (8kV/4kV) – Technical Specifications & Safety Guide

Product Overview

The HET 25kVA exciter transformer delivers precision high-voltage testing with dual-range outputs (8kV/4kV) and ONAN cooling. Designed for industrial applications, it complies with IEC 60076-11 and features advanced electrostatic shielding for stable dielectric performance.

Electrical Parameters

ParameterSpecification
Rated Capacity25kVA
Input Voltage0.38kV
Input Current65.8A
Output Configurations:
• High Range8kV @ 3.125A
• Standard Range4kV @ 6.25A
Frequency50Hz ±1%
Impedance Voltage<4% (per IEEE C57.12.00)

Advanced Protection Systems

1. Overvoltage Protection

  • Piezoresistors on all HV outputs

  • Zinc oxide arresters (IEC 60099-4 compliant)

  • Ground-connected terminals via 10kA surge arresters

2. Insulation & Discharge Control

  • 8kV corona-free HV bushings

  • Electrostatic shield layer between HV windings

  • Isovolumetric capacitance cores for voltage stability

Mechanical Construction

Enclosure Design

  • Steel housing with anti-corrosion coating

  • Wheel-mounted (4× industrial casters)

  • Shell-type oil tank with 30L conservator

Terminal Configuration

  • LV terminals: Porcelain bushings

  • HV terminals: Fiberglass-reinforced bushings

  • Dual corona rings per HV bushing

Winding Technology

Insulation System

  • Cylinder-type winding with balanced capacitance

  • Inter-turn insulation (1mm Nomex® layers)

  • Electrostatic compensation shields for uniform voltage distribution

Dielectric Performance

  • Partial discharge <5pC at 1.1Ur (IEC 60270)

  • Impulse withstand: 95kV (1.2/50μs wave)

  • Power frequency withstand: 18kV/min

Installation & Maintenance

Commissioning Requirements

  • Minimum 1m clearance from grounded surfaces

  • Oil dielectric strength ≥45kV before energization

  • Initial insulation resistance ≥8,000MΩ

Service Schedule

  • Annual oil testing (breakdown voltage, acidity)

  • Bushing inspection every 6 months

  • Winding resistance measurement every 3,000 hours

Typical Applications

  • Power transformer routine testing

  • Cable fault location systems

  • Rotating machine insulation tests

  • High-voltage component R&D

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message