High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

≤100kVA Range

HET 12kVA/4kV Exciter Transformer - Technical Specifications & Protection Features

Professional-grade 12kVA exciter transformer with 4kV output capacity featuring advanced electrostatic shielding, isovolumetric capacitance cores, and zinc oxide overvoltage protection.


  • US$ 2,790.00
  • Lead time: 30 day

>>>WhatsApp Communication<<<

Product Details

Product Tags

HET 12kVA/4kV Exciter Transformer - Technical Specifications & Protection Features

Product Overview

This single-phase 12kVA exciter transformer is engineered for high-voltage testing applications up to 4kV, complying with IEC 60076-11 standards for testing transformers. The unit combines movable design with robust dielectric protection systems for field and laboratory use.

Technical Parameters

SpecificationValue
Rated Capacity12kVA
Voltage Configuration0.4kV / 2kV / 4kV
Current Rating30A (LV) / 3A (HV)
Frequency50Hz ±1%
Impedance Voltage<5% (per IEEE C57.12.00)
Cooling ClassONAN (Oil Natural Air Natural)

Advanced Protection Systems

Overvoltage Protection

  • Piezoresistors on all HV outputs

  • Zinc oxide arresters (IEC 60099-4 compliant)

  • Ground-referenced terminals via 10kA arresters

Corona Prevention

  • 5kV corona-free HV bushings

  • Dual corona rings per HV bushing

  • Isovolumetric capacitance cores

Mechanical Construction

Enclosure Design

  • 15-gauge steel housing with epoxy coating

  • Integrated wheel base (4× industrial casters)

  • Shell-type oil tank with 25L conservator

Terminal Configuration

  • Porcelain bushings for LV connections

  • Fiberglass-reinforced HV bushings

  • Voltage-graded bushing arrangement

Winding Technology

Insulation System

  • Inter-turn insulation layers (0.5mm Nomex)

  • HV-LV electrostatic shielding

  • Balanced capacitance distribution (±3%)

Winding Structure

  • Cylinder-type winding configuration

  • Compound insulation tube skeleton

  • Top-bottom area matching within 5%

Dielectric Performance

  • Partial discharge <10pC at 1.5Ur

  • Impulse withstand 75kV (1.2/50μs wave)

  • Power frequency withstand 10kV/min

Installation & Maintenance

Commissioning Requirements

  • Minimum 800mm clearance from grounded surfaces

  • Oil dielectric strength ≥40kV before energization

  • Initial insulation resistance ≥5000MΩ

Service Schedule

  • Annual oil testing (breakdown voltage, moisture)

  • Bushing cleaning every 6 months

  • Winding resistance measurement every 3 years

Typical Applications

  • Circuit breaker timing tests

  • Power cable withstand testing

  • Rotating machine excitation systems

  • High-voltage component R&D

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message