HVDC Generator
HDCG I-1200kV/30mA HVDC Generator | Precision High Voltage Test System
High Performance Specifications
Ultra-stable output: <1% voltage drop under load
Advanced ripple control: <3% at rated current
Robust construction: 3-stage 400kV voltage multiplication
Standards Compliance
IEC 61643-1:2011 (Surge protective devices)
IEC 61083-1/2 (High-voltage impulse measurement)
IEC 62475 (High-current test techniques)
Technical Specifications
Parameter | Value |
---|---|
Rated Voltage | 1200kV DC |
Rated Current | 30mA |
Ripple Factor | <3% |
Voltage Stability | <1% drop under load |
Polarity Reversal | Manual (~15 minutes) |
Partial Discharge Performance
Endurance Testing:
10 minutes at rated current
120 minutes continuous at 1000kV
Strict PD Limits:
≤9 pulses >2300pC
≤3 pulses >1500pC
Zero flashover/breakdown
System Architecture
3-Stage Voltage Multiplier
400kV per stage configuration
Unilateral unsymmetrical circuit design
Modular Components
Test transformer and regulator on separate platforms
Integrated filter/multi-voltage capacitors
Universal wheel/jack system for mobility
Safety & Customization
Protection Systems:
Specialized 1200kV corona ring
Integrated earthing switch
Configuration Options:
Fixed or mobile versions
Manual polarity reversal
Typical Applications
High-voltage cable testing
Power transformer validation
Research laboratory applications
All performance specifications verified per IEC 61083-2 testing protocols. Custom configurations available for specialized testing requirements.