The GTS 2025 represents the next generation of intelligent control for high-voltage resonant test systems, combining advanced protection features with precise voltage regulation. Designed for demanding laboratory and industrial environments, this system automatically manages voltage rise curves, flashover events, and comprehensive safety interlocks.
Core Functions
Feature | Specification |
---|---|
Main Control Objects | Resonant system, protection circuits, peak voltmeter measurement |
Flashover Response | Automatic HV cutoff within 2ms |
Voltage Rise Control | Manual/Auto modes with programmable curves |
Protection Systems | Over-voltage, over-current, low gas pressure latch-up |
Voltage Adjustment | Continuous output regulation |
Control Voltage | 220V/380V AC 60Hz |
Key Operational Features
1. Intelligent Voltage Management
Dual-speed voltage rise (Fast/Slow modes)
Programmable automatic voltage curves
Continuous output adjustment (0-100% rated voltage)
2. Comprehensive Protection Suite
Instant flashover cutoff (≤2ms response)
External pitch point safety circuit
Over-voltage/current protection (Class III)
Gas pressure monitoring with latch-up
3. Advanced Monitoring & Display
Real-time HV/LV side voltage/current readouts
Quality factor (Q) measurement
Error diagnostics display:
Gas pressure warnings
Short-circuit alerts
System fault codes
System Architecture
Control Console
Withstanding timer (1-9999s programmable)
Audible/visual alarm system
Electric interlock protection
Safety Mechanisms
Voltage regulator auto-zero function
Dual redundant protection circuits
Imported high-reliability components
Technical Advantages
Flashover Safety: Prevents over-voltage generation during test object failures
Precision Control: ±0.5% voltage regulation accuracy
Flexible Operation: Supports both manual and fully automated test sequences
System Integrity: Maintains stable output during network fluctuations
Application Scenarios
Power transformer resonant withstand testing
HV cable commissioning tests
Gas-insulated switchgear (GIS) diagnostics
Research lab high-voltage experiments
Certifications
IEC 61010-1 (Safety requirements)
IEEE Std 433 (Resonant testing)
EN 61326-1 (EMC compliance)
Installation Requirements
Indoor stationary use only
Ambient temperature: -10°C to +40°C