Cable Test Terminal
CTT 500kV Cable Test Termination - Ultra High Voltage Test System
World-Class EHV Testing Solution
The CTT 500kV Cable Test Termination represents the pinnacle of extra high voltage testing technology, delivering unmatched 1300kV impulse capability with precision partial discharge measurement. Designed for cable manufacturers and high-voltage laboratories requiring the most advanced testing capabilities.
Technical Specifications
Electrical Characteristics
Rated System Voltage 500 kV r.m.s.
Partial Discharge Level <2 pC at Un
Lightning Impulse Withstand 1300 kV (Negative Polarity)
Power Supply 220V/20A, 50/60Hz
Mechanical Configuration
Compatible Cable Diameter 133 mm (incl. insulation)
Terminal Tilt Angle 40°
Main Unit Dimensions 1200 × 1400 × 1700 mm
Installation Footprint 4000 × 1200 mm
Dry Weight 272 kg
Thermal Management
Cooling Capacity 60 kW
Water Capacity 500 liters
Max Operating Temperature 60°C
Cooling Water Temperature ≤20°C
Water Flow Rate ≥45 l/min
Installation Parameters
Cable Mounting Height 1500 mm
Terminal Mounting Height 4200 mm
Minimum HV Clearance 2300 mm
Terminal Assembly Weight 450 kg (pair)
Environmental Specifications
Ambient Temperature Range 3°C to 35°C
System Pressure Rating 4 atm
Water Conductivity 0.1-2 μS/cm
Hydraulic Connections 1" pipe, 3/4" head
Key Benefits
Unmatched Voltage Range
500kV AC with 1300kV impulse capability for testing next-generation cable systems
Precision Measurement
<2 pC partial discharge sensitivity for detecting minute insulation defects
Enhanced Safety
2300mm minimum clearance and 4200mm terminal height ensure operator protection
Robust Construction
450kg terminal assemblies provide exceptional stability during impulse testing
Optimized Ergonomics
1500mm cable height and 40° terminal angle for operator convenience
Reliable Performance
4atm pressure rating and wide temperature range for demanding environments
Typical Applications
Type testing of 500kV class extra high voltage cables
Partial discharge measurement and location
Lightning impulse withstand testing (1300kV)
Factory acceptance testing for ultra high voltage cable systems
Research and development of advanced cable insulation materials
Quality assurance in EHV cable manufacturing
Condition assessment of installed high voltage cables
Standards Compliance
Meets or exceeds requirements of:
IEC Standards
IEC 60840 (Power cables with extruded insulation)
IEC 60270 (Partial discharge measurements)
IEC 60060-1 (High-voltage test techniques)
IEEE Standards
IEEE 400.2 (VLF testing of shielded power cables)
IEEE 48 (Test procedures for HV cable terminations)
Safety Standards
OSHA 1910.269 (Electric power generation)
NFPA 70E (Electrical safety in workplaces)
Technical Notes
The system's 40° terminal tilt angle optimizes electric field distribution during high voltage tests. The 2300mm minimum clearance distance meets international safety requirements for 500kV systems. For optimal performance, maintain water conductivity between 0.1-2 μS/cm and ensure cooling water temperature remains below 20°C. The 450kg terminal assemblies provide exceptional mechanical stability during impulse testing sequences.