High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

Resonant Control System

ACS-2025 Digital Control System for Resonant Test | PLC-Based HV Measurement (1650kV Max)

Advanced ACS-2025 system features PLC control, 0.1kV voltage accuracy, and 1650kV max output. Includes fiber-optic isolation, Omron/Siemens components, and 10ms over-current protection.


>>>WhatsApp Communication<<<

Product Details

Product Tags

ACS-2025 Digital Control System for Resonant Test Applications

The ACS-2025 represents the next generation of high-voltage test control, combining PLC automation with military-grade protection for resonant test systems up to 1650kV. Engineered with Omron/Siemens components and fiber-optic isolation for maximum safety.

System Highlights

  • 1650kV maximum configurable output

  • 0.1kV voltage setting accuracy

  • 10ms over-current response

  • ✅ Dual control modes: Automatic/Manual

Core Specifications

ParameterSpecification
Control Voltage220V/50Hz (≤10A)
Voltage Rise Rate1kV/s ±10% (adjustable)
Timing Range1-99 hours (programmable)
Measurement AccuracyClass 1 (all meters)
Component BrandsOmron, Siemens (contactors/relays)

Key Functional Modules

1. Intelligent Control System

  • PLC-based automation with touchscreen interface

  • Fiber-optic isolated communication (2-core)

  • Automatic zero-position recovery

2. Precision Measurement

  • 7-channel digital displays (all Class 1 accuracy):

    • Winding voltmeter

    • Capacitive divider voltmeter

    • Regulator I/O ammeters

    • Test transformer meters

  • Discharge voltage recording

3. Multi-Layer Protection

  • 10ms fast-recovery over-voltage protection

  • Programmable current/voltage thresholds

  • 3-stage mechanical/electrical interlocks:

    1. Door-open prevention

    2. Zero-position verification

    3. Emergency stop cascade

Operational Workflow

Step 1: Preset Parameters

Set voltage (0.1kV steps), ramp rate, and test duration via touchscreen

Step 2: Automated Test Sequence

  • 75% voltage: Fast ramp (3kV/s)

  • 75-100%: Precision ramp (0.5kV/s)

Step 3: Protective Monitoring

Continuous comparison of reference vs. actual voltage (Δ<1%)

Industry Applications

  • Cable Manufacturing: Partial discharge testing

  • Utility Companies: Transformer frequency response analysis

  • Research Labs: Dielectric material evaluation

  • Aviation: Aircraft component HV validation

Maintenance Tip: Perform optical fiber connector inspection every 500 test cycles to maintain signal integrity.

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message