DC Hipot
800W-200KV/400KV HVDC Hi-pot Test System
Ultra-high voltage testing solution delivering 800W continuous power at either 200KV/4mA or 400KV/2mA configurations for the most demanding dielectric tests.
Technical Specifications
Operating Mode | Voltage | Current | Power |
---|---|---|---|
High Current | 200KV (±1%) | 4mA (±1%) | 800W |
Ultra High Voltage | 400KV (±1%) | 2mA (±1%) | 800W |
Common Specifications: ≤1% ripple | 0.05% stability option | ±1% overvoltage setting |
System Configuration
Core Components
Control Unit: 6kg with digital interface
Multiplier Stage: 14kg (2000mm height)
Insulation: Epoxy FRP cylinder
Measurement Systems
2V-B shielded microammeter
Optional HV-B infrared ammeter
Multi-point auto-test sequencing
Key Features
Ultra-HV Performance
400KV maximum output
1.25× overload capacity
No test object capacitance limits
Precision Control
0.05% stability option
Programmable test sequences
Touch-button operation
Test Applications
200KV/4mA Mode
MOA arrester leakage analysis
EHV cable factory tests
Transformer insulation tests
400KV/2mA Mode
Ultra-HV equipment certification
Transmission system components
Research facility testing
Environmental Specifications
Parameter | Specification |
---|---|
Temperature Range | -10°C to +40°C |
Humidity | <85% RH (non-condensing) |
Altitude | <1500m |
Power Supply | 220V AC ±10%, 50Hz |
Standards Compliance
DL/T 848.1-2004 HV Test Equipment Standards
2BF24003-90 Portable DC Generator Specs
IEC 60060-1 Dielectric Test Methods
Technical Legacy
Building on our 1992 introduction of China's first PWM-regulated DC HV generator, this 400KV system represents our most advanced solution with 2,857+ units deployed through 2013.
Available with optional infrared measurement or as part of complete test systems - contact our HV engineers for application-specific configurations.