DC Hipot
120W-60KV HVDC Hi-pot Test System
Precision DC high-voltage test set for dielectric withstand and leakage current measurement, featuring PWM regulation and dual-stage voltage multiplier technology.
Technical Specifications
| Parameter | Specification |
|---|---|
| Output Voltage | 0-60KV (±1%) |
| Output Current | 0-2mA (±1%) |
| Ripple Factor | ≤1% |
| Overvoltage Setting | ±1% accuracy |
| Weight | 4kg (controller) + 4kg (multiplier) |
| Multiplier Dimensions | 110×520mm |
Key Features
Precision Measurement
Fully-shielded micro-ammeter
0.05% stability option
Coaxial test cables
Advanced Protection
Arc-tolerant design
Ground loop monitoring
Open-circuit safeguards
Test Applications
MOA Arresters: Leakage current characterization
Power Cables: Dielectric withstand testing
Transformers: Insulation integrity verification
Switchgear: DC hi-pot acceptance tests
Industry Compliance
DL/T 848.1-2004 HV Test Equipment Standards
2BF24003-90 Portable DC Generator Specs
IEC 60060-1 Dielectric Test Methods
Fault Diagnosis Guide
Understanding Breakdown Phenomena
During cable DC testing, two fault types may occur:
| Fault Type | Characteristics | Test Indications |
|---|---|---|
| Leakage Fault | Linear current-voltage relationship | Gradual current rise before breakdown |
| Flashover Fault | Non-linear breakdown | Sudden discharge at threshold voltage |
Flashover faults indicate weak insulation points without permanent channels - evidenced by temporary breakdowns that self-recover when voltage is removed.
Operational Modes
Manual Ramp: User-controlled voltage increase
Auto Sequence: Programmed multi-point testing
Leakage Scan: Current measurement at preset levels
Configured for your specific test requirements - choose optional infrared ammeter or integrated 40kV units for field testing.