HET 30kVA Variable Frequency Exciter Transformer (1.5kV/0.35kV) – Technical Specifications

High-performance 30kVA exciter transformer with 1.5kV/0.35kV outputs and 30-300Hz frequency range. Features <5pC partial discharge and continuous operation capability for demanding test applications.


  • US$ 4,919.00
  • Lead time: 30 day

>>>WhatsApp Communication<<<

Product Details

Product Tags

HET 30kVA Variable Frequency Exciter Transformer (1.5kV/0.35kV) – Technical Specifications

Product Overview

The HET 30kVA exciter transformer is engineered for precision testing across a wide frequency range (30-300Hz), delivering dual voltage outputs (1.5kV/0.35kV). With ONAN cooling and ultra-low partial discharge (<5pC), it supports continuous operation at full rated capacity.

Electrical Specifications

ParameterSpecification
Rated Capacity30kVA
Frequency Range30-300Hz
Input Voltage350V
Input Current85.7A (max)
Short Circuit Impedance≤5%
Partial Discharge≤5pC
Noise Level≤65dB

Thermal Performance

  • Continuous operation at rated voltage/current

  • Winding temperature rise: ≤65K

  • Oil temperature rise: ≤55K

  • Cooling method: ONAN (Oil Natural Air Natural)

Advanced Protection Systems

1. Overvoltage Protection

  • Piezoresistors on all HV outputs

  • Zinc oxide arresters (IEC 60099-4 compliant)

  • Ground-connected via 15kA surge arresters

2. Insulation & Discharge Control

  • 1.5kV corona-free HV bushings

  • Electrostatic shield layer between windings

  • Isovolumetric capacitance cores

Mechanical Design

Enclosure Features

  • Steel housing with corrosion-resistant coating

  • Wheel-mounted (4× industrial casters with brakes)

  • Shell-type oil tank with 40L conservator

Terminal Configuration

  • LV terminals: High-strength porcelain bushings

  • HV terminals: Fiberglass-reinforced epoxy bushings

  • Corona rings on all HV bushings

Winding Technology

  • Cylinder-type winding with balanced capacitance

  • Electrostatic compensation shields

  • Inter-turn insulation (1.2mm Nomex® layers)

  • Compound insulation tube skeleton

Installation & Maintenance

Commissioning Requirements

  • Minimum 1m clearance from grounded surfaces

  • Oil dielectric strength ≥45kV before use

  • Initial insulation resistance ≥8,000MΩ

Service Schedule

  • Monthly: Bushing inspection

  • Quarterly: Oil testing (BDV, moisture)

  • Annual: Winding resistance measurement

Typical Applications

  • Variable frequency resonance testing systems

  • Power cable partial discharge measurement

  • Rotating machine insulation diagnostics

  • Transformer factory acceptance tests